Operation
8
311833F
Operation
Pressure Relief Procedure
1.
Engage trigger lock.
2.
Close the bleed-type master air valve.
3.
Disengage the trigger lock.
4.
Hold a metal part of the gun firmly to a grounded
metal pail. Trigger the gun to relieve pressure.
5.
Engage the trigger lock.
6.
Open all fluid drain valves in the system, having a
waste container ready to catch drainage. Leave
drain valve(s) open until you are ready to spray
again.
7.
If you suspect the spray tip or hose is clogged or
that pressure has not been fully relieved after follow-
ing the steps above, VERY SLOWLY loosen tip
guard retaining nut or hose end coupling to relieve
pressure gradually, then loosen completely. Clear
hose or tip obstruction.