background image

Warnings 

4

311833F

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back 
to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where 
applicable.

WARNING

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system 
component. See 

Technical Data

 in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See 

Technical Data 

in all

 

equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information 
about your material, request MSDS forms from distributor or retailer.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-
facturer’s replacement parts only.

Do not alter or modify equipment.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

TOXIC FLUID OR FUMES HAZARD

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or 
swallowed.

Read MSDS’s to know the specific hazards of the fluids you are using.

Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.

Always wear impervious gloves when spraying or cleaning equipment.

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent 
fire and explosion:

Use equipment only in well ventilated area.

Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop 
cloths (potential static arc). 

Keep work area free of debris, including solvent, rags and gasoline.

Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes 
are present.

Ground all equipment in the work area. See 

Grounding 

instructions.

Use only grounded hoses.

Hold gun firmly to side of grounded pail when triggering into pail.

If there is static sparking or you feel a shock, 

stop operation immediately.

 Do not use equipment 

until you identify and correct the problem.

Keep a 

working

 fire extinguisher in the work area.

Summary of Contents for P06DCK

Page 1: ...SG P06MSG 620 psi 4 2 MPa 42 7 bar Maximum Working Pressure 100 psi 0 69 MPa 6 9 bar Maximum Air Inlet Pressure Models P10DCK P10ECK P10LCK P10MCK P10LCS 1180 psi 8 14 MPa 81 4 bar Maximum Working Pre...

Page 2: ...Procedure 8 Maintenance 9 Shutdown 9 Care of the Pump 9 Flushing 9 Lubrication 9 Troubleshooting 11 Repair 12 Required Tools 12 Disconnect the Lower 12 Reconnect the Lower 13 Models P06DCK P06ECK P06...

Page 3: ...otor with DataTrak M stainless steel construction S PTFE PTFE packing configuration G To order replacement parts see Parts List section starting on page 15 The digits in the matrix do not correspond t...

Page 4: ...reas sharp edges moving parts and hot surfaces Do not kink or over bend hoses or use hoses to pull equipment Keep children and animals away from work area Comply with all applicable safety regulations...

Page 5: ...t with protective guards or covers removed Pressurized equipment can start without warning Before checking moving or servicing equipment follow the Pressure Relief Procedure in this manual Disconnect...

Page 6: ...or cardboard which interrupts grounding continuity To maintain grounding continuity when flushing or relieving pressure hold metal part of the spray gun firmly to the side of a grounded metal pail the...

Page 7: ...fluid pressure Gun or valve to dispense fluid Fluid line swivel for easier gun movement Suction kit enables the pump to draw fluid from a container Flush Before Using Equipment The equipment was teste...

Page 8: ...gage the trigger lock 6 Open all fluid drain valves in the system having a waste container ready to catch drainage Leave drain valve s open until you are ready to spray again 7 If you suspect the spra...

Page 9: ...ay tip before flushing Start the pump Hold a metal part of the gun firmly to the side of a grounded metal pail and use the lowest possible fluid pressure during flush ing When flushing is complete rel...

Page 10: ...Maintenance 10 311833F...

Page 11: ...ves PROBLEM CAUSE SOLUTION Pump does not operate or no fluid flow Loose or broken pump parts Disassemble check repair Restricted line or inadequate air supply Clear increase Exhausted fluid supply Ref...

Page 12: ...he coupling nut 3 from the connecting rod adapter 5 Remove the coupling collars do not lose or drop them See FIG 3 5 Hold the tie rod flats with a wrench to keep the rods 6 from turning Unscrew the nu...

Page 13: ...he Lower Place the lower 2 on the tie rods 6 5 Screw the nuts 7 onto the tie rods 6 and torque as noted in FIG 3 6 Screw the coupling nut 3 onto the connecting rod adapter 5 loosely Hold the connectin...

Page 14: ...Repair 14 311833F Models P06DSG P06ESG P06LSG P06MSG Models P06DCK P06ECK P06LCK P06MCK P10DCK P10ECK P10LCK P10MCK P10LCS FIG 4 6 7 3 4 5 15 1 ti8334b 2 FIG 5 ti8335b 6 7 3 4 5 15 1 2...

Page 15: ...1 MOTOR 3400 low noise datatrak see manual 311238 N34LT0 1 2 PUMP see manual 311717 253597 253597 253597 253597 1 3 NUT coupling 184096 184096 184096 184096 1 4 COLLAR coupling 184130 184130 184130 18...

Page 16: ...6 311833F Dimensions B A ti8377b Pump Model A in mm B in mm Approx Weight lb kg P06_SG 41 6 1055 28 0 711 113 51 P06_CK 41 6 1055 28 0 711 113 51 P10_CK 41 6 1055 28 0 711 132 62 P10_CS 41 6 1055 28 0...

Page 17: ...ing Hole Diagram NXT Model 3400 NXT Model 6500 TI8069A TI8070A 6 180 in 157 mm Three 5 8 11 Tie Rod Holes Six 5 8 11 Tie Rod Holes 6 180 in 157 mm 6 186 in 157 mm 6 186 in 157 mm Four 3 8 16 Mounting...

Page 18: ...e gpm lpm All P06 _ _ _ Models 620 4 2 42 100 0 69 6 9 See Performance Chart 17 4 65 8 All P10 _ _ _ Models 1180 8 14 81 4 100 0 69 6 9 17 4 65 8 A 0 7 MPa 7 bar 100 psi air pressure or 10 5 MPa 105 b...

Page 19: ...arbon Steel 1000cc Pump with NXT Model 6500 Air Motor Fluid Pressure A B psi MPa bar 700 4 8 48 600 4 1 41 500 3 4 34 400 2 7 27 300 2 0 20 200 1 3 13 100 6 8 68 0 Fluid Flow in gpm lpm C A B C Air Fl...

Page 20: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANT...