Installation
309967G
9
Models 246914, 246917, 253387, 253390
and 25C689
1. Remove the cover from the pail, and scoop the
lubricant from the center to the sides of the pail to
make its surface concave.
2. Center the follow plate (5) in the pail opening. Press
the follow plate firmly downward and rotate it over
the lubricant surface to eliminate air pockets and
prevent channeling.
3. Place the cover (4) on the pail and tighten the
thumbscrews (A).
4. Install shim (11) on top of cover. Insert the pump
riser tube through the top of the shim (11) and
cover (4). Lower pump until it rests on the shim and
cover.
5. Connect the swivel adapter to the pump fluid out
-
let. Connect fluid hose (3c) to the swivel adapter.
Connect a suitable dispense valve.
For model 25C689 only: Assemble the gun and
hose. Then connect hose to the pump fluid outlet.
6. Connect the swivel adapter to the pump air inlet or
air regulator (9b), whichever is applicable. Connect
the air hose (3a) to the swivel. Connect the air hose
to the air accessories.
F
IG
. 4: Model 253390
F
IG
. 5: Model 253387
3a
5
4
9b
3c
11
8729
5
A
4
9b
3a
3c
11