Grounding
To reduce the risk of static sparking, ground the pump
and all other components used or located in the
dispensing area. Check your local electrical code for
detailed instructions for your area and type of
equipment.
Ground this equipment:
Pump:
remove the ground screw (Z) and insert through
the eye of the ring terminal at end of ground wire (Y).
Fasten the ground screw back onto the pump and
tighten securely. Connect the other end of the ground
wire to a true earth ground. See F
To order a
ground wire and clamp, order Part No. 222011.
Air and fluid hoses:
use only grounded hoses.
Air compressor:
follow manufacturer’s recommenda
-
tions.
Dispense valve:
ground through connection to a prop
-
erly grounded fluid hose and pump.
Fluid supply container:
follow local code.
To maintain grounding continuity when flushing or
relieving pressure:
hold metal part of the dispense
valve firmly to the side of a grounded metal pail, then
trigger the valve.