Repair
3A3169E
13
Repair
Seal Replacement
NOTE:
For most seal replacement procedures, the
pump should be completely removed from service and
clamped in a vise. If you are only replacing the reservoir
and/or reservoir seals, you do not have
to remove the
pump from it’s service location. The following instruc-
tions cover the complete disassembly of the pump. Your
pump repair may not require total pump disassembly.
Disassembly
1.
Turn off air supply and disconnect air lines to the
pump.
2.
Disconnect electrical connections to lubrication con-
troller.
3.
Close
shut-off valve (V)
to turn off
oil input supply
pump/system (DD)
.
4.
Relieve pressure
(page 9).
5.
Disconnect
supply line (G)
from the
pump outlet
(E)
.
6.
Slowly loosen and remove oil input line from the
pump base and drain oil from the pump (F
. 13).
NOTE:
Removing the oil input line slowly will help
prevent splashing while the oil drains from the reser-
voir.
7.
Remove mounting bolts (F
. 14) and remove the
pump from service.
8.
Clamp the pump base in a vise as shown in F
Use a soft-jaw vise or place a rag in the vise jaws to
protect the surface of the pump base.
9.
Collect drained oil in a pail or waste container. Dis-
pose of oil according to all regulations for proper dis-
posal.
F
IG
. 13
F
IG
. 14
F
IG
. 15