Troubleshooting
332252A
13
Sprayer does not run at all
Check to see if control board is over
heating.
1.
Set sprayer to OFF and disconnect power to
sprayer.
2.
Make sure motor air intake is not blocked.
3.
Make sure fan has not failed.
4.
Make sure control board is properly secured to back
plate and that conductive thermal paste is used on
power components.
5.
Replace control board.
6.
Replace motor.
Digital display shows E=10
Control board status light blinks
10 times repeatedly
TYPE OF PROBLEM
WHAT TO CHECK
HOW TO CHECK