Troubleshooting
334627K
17
Check Heater
Check the continuity of the heater to verify proper
resistance. If there is no continuity, the heater has failed
and needs to be replaced.
1.
Disable the applicator. See
Before Beginning
Repair
on page
.
2.
Check the resistance of the heater using a
multi-meter between the pins of the cordset
connector. See the illustrations of the two types of
connectors in
Table 1
and
Table 2
on this page.
3.
Replace the heater cartridge if the resistance
reading is outside the range or if there is no
continuity. See
Replace Heater Cartridge
on page
.
Table 1: 24W087, 24X039, 24X760, or 25E783 Pt 100
(385) RTD Cordset
Table 2: 24W088, 24X040, or 24X761 Ni 120 RTD
Cordset
Cordset
Check Pins
Model
Resistance
Values
24W087,
24X039,
24X760, or
25E783 Pt
100 (385)
RTD
Cordset
A and C
Slim Models
365-405
Ohms
Dual and Dual
Low Profile
Models
180-200
Ohms
Quad and
Quad Low
Profile Models
145-165
Ohms
24W088,
24X040, or
24X761 Ni
120 RTD
Cordset
1 and 2
Slim Models
365-405
Ohms
Dual and Dual
Low Profile
Models
180-200
Ohms
Quad and
Quad Low
Profile Models
145-165
Ohms
Pin
Description
A
Thermal Cutoff
B
Ground
C
Heat
D
RTD (White)
E
RTD (Red)
Pin
Description
1
Thermal Cutoff
2
Heat -
3
RTD (White)
4
RTD (Red)
G
Ground
Summary of Contents for InvisiPac GM100 Plug-Free