6
307010
Operation
WARNING
To reduce the risk of serious injury,
whenever you are instructed to relieve
pressure, follow the
Pressure Relief
Procedure
on page 4.
Whenever you stop spraying for a moment, en-
gage the gun safety latch. See Fig. 2.
SKIN INJECTION HAZARD
WARNING
The wallet-sized warning card provided with this
gun should be kept with the operator at all times.
The card contains important treatment informa-
tion should an injection injury occur. Additional
cards are available at no charge from Graco Inc.
1.
Start the pump. Adjust the fluid pressure so the
spray is completely atomized. Always use the
lowest pressure necessary to get the desired
results. Higher pressure may not improve the
spray pattern and will cause premature tip and
pump wear.
2.
If adjusting the pressure does not give a good
spray pattern, try another tip size. Be sure to relive
pressure completely before changing tips.
3.
Use a full-open, full-close trigger action. Hold the
gun about 14 in. (350 mm) from and at right angles
to the work surface. Do not swing the gun in an
arc. Practice to find the best length and speed of
stroke.
Fig. 2
8122
Safety Off