2
307010
Table of Contents
Setup
4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation
5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operation
6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting
8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service
9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts
10
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tip Selection Chart
12
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data
13
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Graco Standard Warranty
14
. . . . . . . . . . . . . . . . . . . . . .
Graco Information
14
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Symbols
Warning Symbol
WARNING
This symbol alerts you to the possibility of serious
injury or death if you do not follow the instructions.
Caution Symbol
CAUTION
This symbol alerts you to the possibility of damage to
or destruction of equipment if you do not follow the
instructions.
WARNING
EQUIPMENT MISUSE HAZARD
Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result
in serious injury.
D
This equipment is for professional use only.
D
Read all instruction manuals, tags, and labels before operating the equipment.
D
Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco
distributor.
D
Do not alter or modify this equipment. Use only genuine Graco parts and accessories.
D
Check the equipment daily. Repair or replace worn or damaged parts immediately.
D
Do not exceed the maximum working pressure of the lowest rated system component. This equip-
ment has a
1000 psi (6.9 MPa, 69 bar) maximum fluid working pressure
.
D
Route the hoses away from the traffic areas, sharp edges, moving parts, and hot surfaces. Do not
expose Graco hoses to temperatures above 180
_
F (82
_
C) or below –40
_
F (–40
_
C).
D
Do not use the hoses to pull the equipment.
D
Use only Graco approved hoses. Do not remove hose spring guards, which help protect the hose
from rupture caused by kinks or bends near the couplings.
D
Use fluids or solvents that are compatible with the equipment wetted parts. See the
Technical
Data
section of all the equipment manuals. Read the fluid and solvent manufacturer’s warnings.
D
Comply with all applicable local, state and national fire, electrical and other safety regulations.
TOXIC FLUID HAZARD
Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin,
inhaled, or swallowed.
D
Know the specific hazards of the fluid you are using.
D
Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local,
state and national guidelines.
D
Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and
solvent manufacturer.