Installation
Changing the Orientation of the Fluid Inlet
and Outlet Ports (Husky 515)
You can change the orientation of the fluid inlet and out-
let ports by repositioning the manifolds. For Husky 515,
see
. For Husky 716, see
1.
Relieve the pressure. See
2. Remove the four manifold nuts (109) or bolts (105).
3. Turn the manifold to the desired position, reinstall the
nuts or bolts, and torque to 80 to 90 in-lb (9 to 10
NSm). See
NOTE:
Make sure all manifold o-rings are positioned
correctly before you fasten the manifold. Manifold
o-rings (139) are shown in
.
NOTE:
Pumps with duckbill check valves are shipped
with the inlet manifold on top and the outlet manifold on
the bottom. See page 14 for details.
1
1
109
9065A
1
109
Torque to 80 to 90 in-lb (9 to 10 NSm). See
outlet
inlet
Fig. 4
f
1
1
105
9071A
1
105
Torque to 80 to 90 in-lb (9 to 10 NSm). See
outlet
inlet
Fig. 5