background image

30

308368

Graco Warranties

Graco Standard Husky Pump Warranty

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the
date of sale by an authorized Graco distributor to the original purchaser for use.  With the exception of any special, extended, or limited
warranty published by Graco, Graco will, for a period of five years from the date of sale, repair or replace any part of the equipment
determined by Graco to be defective.  This warranty applies only when the equipment is installed, operated and maintained in accor-
dance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by
faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub-
stitution of non-Graco component parts.  Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of
Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture,
installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for
verification of the claimed defect.  If the claimed defect is verified, Graco will repair or replace free of charge any defective parts.  The
equipment will be returned to the original purchaser transportation prepaid.  If inspection of the equipment does not disclose any defect
in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and
transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT
NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. 

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above.  The buyer agrees that no other
remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any
other incidental or consequential loss) shall be available.  Any action for breach of warranty must be brought within six years of the date
of sale.

Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection
with accessories, equipment, materials or components sold but not manufactured by Graco.  These items sold, but not manufactured
by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer.  Graco will provide
purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment
hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract,
breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings
entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English.  Les parties reconnais-
sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires
exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les  procedures concernées.

Extended Product Warranty

Graco warrants all Husky 205, 307, 515, 716, 1040, 1590, 2150, and 3275 air valve center sections to be free from defects in material
and workmanship for a period of fifteen years from date installed in service by the original purchaser. Normal wear of items such as
packings or seals are not considered to be defects in material and workmanship.

Five years

Graco will provide parts and labor.

Six to Fifteen years

Graco will replace defective parts only.

Graco Information

TO PLACE AN ORDER

, contact your Graco distributor, or call one of the following numbers

to identify the distributor closest to you:

1–800–367–4023 Toll Free

612–623–6921

612–378–3505 Fax

All written and visual data contained in this document reflect the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

Sales Offices:

 Minneapolis, Detroit

International Offices:

 Belgium, Korea, Hong Kong, Japan

www.graco.com

PRINTED IN USA   308368   10/1994, Revised 06/2002

Summary of Contents for Husky 2150

Page 1: ...ps Model No DFH Aluminum Extended Pump Model No DF4 Stainless Steel Pumps Model No DF6 Ductile Iron Pumps Model No DFC Aluminum BSPT Pumps Model No DFD Stainless Steel BSPT Pumps Model No DFF Ductile...

Page 2: ...Observe all warnings Read and understand all instruction manuals warning labels and tags before operating the equipment D Never alter or modify any part of this equipment doing so could cause it to m...

Page 3: ...ing pumped dust particles and other flammable substances whether you are pumping indoors or out doors and can cause a fire or explosion and serious injury and property damage D To reduce the risk of s...

Page 4: ...irst day of operation check and retorque the fasteners again Although the recommended frequency for retorquing fasteners varies with pump usage a general guideline is to retorque fasteners every two m...

Page 5: ...se it to relieve trapped air See the WARNING above Locate the other master air valve E upstream from all air line accessories and use it to isolate them during cleaning and repair c The air line filte...

Page 6: ...toff valve K in the fluid outlet line Retorquing with TeflonR Seals or Diaphragms If your pump has TeflonR seals in the manifolds or if it has TeflonR diaphragms retorque the manifold bolts 106 and fl...

Page 7: ...02 101 106 112 2 Apply medium strength blue LoctiteR or equivalent to the threads Torque to 190 to 220 in lb 22 to 25 N m 2 106 2 Fluid Pressure Relief Valve Some systems may require installation of a...

Page 8: ...t is 3 4 npt f Do not restrict the air exhaust port Excessive exhaust restriction can cause erratic pump operation To provide a remote exhaust 1 Remove the muffler P from the pump air exhaust port 2 I...

Page 9: ...rts to cycle Allow the pump to cycle slowly until all air is pushed out of the lines and the pump is primed If you are flushing run the pump long enough to thoroughly clean the pump and hoses Close th...

Page 10: ...sh the pump and follow the Pressure Relief Procedure Warning on page 9 before storing it for any length of time Use a compat ible solvent Tightening Threaded Connections Before each use check all hose...

Page 11: ...ured Replace See pages 15 to 17 Restricted exhaust Remove restriction Air bubbles in fluid Suction line is loose Tighten Diaphragm ruptured Replace See pages 15 to 17 Loose inlet manifold 102 damaged...

Page 12: ...dle nose pliers pull the pilot block 18 straight up and out of the cavity See Fig 7 4 Pull the two actuator pistons 11 out of the bear ings 12 Remove the u cup packings 10 from the pistons Pull the pi...

Page 13: ...in 16 Grease the pins and o rings Insert the pins into the bearings 15 narrow end first See Fig 8 5 Install a u cup packing 10 on each actuator piston 11 so the lips of the packings face the narrow en...

Page 14: ...to the fluid covers 101 See Fig 10 4 Remove the seats 201 balls 301 and o rings 202 from the manifold NOTE Some models do not use o rings 202 5 Turn the pump over and remove the inlet manifold 102 Re...

Page 15: ...e 401 Use all the parts in the kit for the best results 1 Follow the Pressure Relief Procedure Warning on page 9 2 Remove the manifolds and disassemble the ball check valves as explained on page 14 3...

Page 16: ...ring 108 on the shaft bolt 107 b Install the fluid side diaphragm plate 105 on the bolt so the rounded side faces in toward the diaphragm 401 c On TeflonR Models only install the TeflonR diaphragm 403...

Page 17: ...with Diaphragms Removed 1 Lips face out of housing 1 Rounded side faces diaphragm 401 Air Side must face center housing 1 1 Grease Apply medium strength blue LoctiteR or equivalent Torque to 20 to 25...

Page 18: ...earings 19 reach into the center housing 1 with an o ring pick and hook the u cup packings 402 then pull them out of the housing Inspect the packings See Fig 12 Reassembly 1 If removed install the sha...

Page 19: ...16 H M Insert bearings tapered end first Press fit bearings flush with surface of center housing 1 Apply medium strength blue LoctiteR or equivalent to the threads Torque to 120 to 150 in lb 14 to 17...

Page 20: ...x do not correspond to the ref nos in the parts drawing and lists on pages 22 and 23 Diaphragm Pump Air Motor Fluid Section Seats Balls Diaphragms 232503 aluminum aluminum Hytrelr acetal Hytrelr D for...

Page 21: ...he parts list for example 201 For example if your pump has polypropylene seats TeflonR balls and TeflonR diaphragms you need to order Repair Kit D 0 F 9 1 1 The digits in the matrix do not correspond...

Page 22: ...g labels tags and cards are available at no cost These parts are unique to remote piloted air motor DG _ _ _ _ Z These parts are used on extension version only Ref No 106 is qty 20 on extension versio...

Page 23: ...buna N 2 18 188614 BLOCK pilot acetal 1 19 188609 BEARING shaft acetal 2 20 116343 SCREW grounding 1 22 188603 GASKET air cover foam 2 23 23 189300 195919 COVER air aluminum COVER air 2150 remote 2 2...

Page 24: ...NG TeflonR 2 110 Y 188621 LABEL warning 1 111 102656 MUFFLER 1 112 112543 SCREW M10 x 1 50 110 mm 4 33 in stainless steel 8 Digit Ref No Part No Description Qty C 101 15A612 COVER fluid aluminum 2 102...

Page 25: ...eflonR 4 Ball Parts List Matrix Column 5 Digit Ref No Part No Description Qty 1 301 112359 BALL TeflonR 4 2 301 112363 BALL acetal 4 4 301 112360 BALL 440C SS 4 5 301 112745 BALL HytrelR 4 6 301 11236...

Page 26: ...haust muffler included J F H G E FRONT VIEW B A 6 0 in 152 5 mm K 2 in 50 8 mm port diameter SIDE VIEW 6 25 in 158 8 mm 12 5 in 317 5 mm 45_ 6 0 in 152 5 mm PUMP MOUNTING HOLE PATTERN four 0 625 in 16...

Page 27: ...165 1 mm E 17 45 in 443 2 mm 17 45 in 443 2 mm 17 45 in 443 2 mm 18 07 in 458 9 mm F 19 9 in 505 5 mm 22 88 in 579 1 mm 19 37 in 492 0 mm 22 27 in 565 7 mm G 21 9 in 556 3 mm 24 88 in 631 9 mm 21 37...

Page 28: ...MPa 4 8 bar and 50 cpm 85 dBa Maximum operating temperature 150_ F 65 5_ C 200_ F 93 3_ C for models with TeflonR diaphragms Air inlet size 1 2 npt f Fluid inlet size 2 npt f Fluid outlet size 2 npt...

Page 29: ...tal scale at 40 psi 0 28 MPa 2 8 bar discharge head pressure vertical scale requires approximately 60 scfm 1 68 m3 min air consumption at 70 psi 0 49 MPa 4 9 bar inlet air pressure FLUID FLOW GPM lpm...

Page 30: ...ntal or consequential loss shall be available Any action for breach of warranty must be brought within six years of the date of sale Graco makes no warranty and disclaims all implied warranties of mer...

Reviews: