Technical
Technical
Technical Data
Data
Data
Husky
Husky
Husky 15120
15120
15120 Diaphragm
Diaphragm
Diaphragm Pump
Pump
Pump
US
US
US
Metric
Metric
Metric
Maximum fluid working pressure
125 psi
0.86 MPa, 8.6 bar
Air pressure operating range
20 to 125 psi
0.14 to 0.86 MPa, 1.4 to 8.6 bar
Air inlet size
1/2 in. (npt(f)
Air exhaust size
1 in.
Fluid inlet and outlet size
(ANSI/DIN flange)
1.5 in
38 mm
Maximum suction lift (reduced
if balls don’t seat well due
to damaged balls or seats,
lightweight balls, or extreme speed
of cycling)
Wet:
31 ft
Dry: 16 ft
Wet:
9.4 m
Dry: 4.9 m
Maximum size pumpable solids
1/4 in.
6.3 mm
Minimum ambient air temperature
for operation and storage.
NOTE:
NOTE:
NOTE: Exposure to extreme
low temperatures may result in
damage to plastic parts.
32° F
0° C
Air Consumption
43 scfm at 70 psi, 60 gpm
1.2 m
3
/min at 0.48 MPa, 4.8
bar, 227 lpm
Maximum Air Consumption
85 scfm
2.4 m
3
/min
Noise
Noise
Noise (dBa)
(dBa)
(dBa)
Sound power measured per ISO-9614–2. Sound pressure was tested 3.28 ft (1 m) from equipment.
90.9 at 70 psi and 50 cpm
90.9 at 4.8 bar and 50 cpm
Sound Power
102.1 at 100 psi and full flow
102.1 at 7.0 bar and full flow
83.6 at 70 psi and 50 cpm
83.6 at 4.8 bar and 50 cpm
Sound Pressure
95.7 at 100 psi and full flow
95.7 at 7.0 bar and full flow
Fluid
Fluid
Fluid flow
flow
flow per
per
per cycle
cycle
cycle
1–piece bolt-through diaphragms
0.63 gallons
2.4 liters
2–piece bolt-through diaphragms
0.66 gallons
2.5 liters
Overmolded diaphragms
0.59 gallons
2.3 liters
Maximum
Maximum
Maximum free
free
free---flow
flow
flow delivery
delivery
delivery
1–piece bolt-through diaphragms
122 gpm
462 lpm
2–piece bolt-through diaphragms
120 gpm
454 lpm
Overmolded diaphragms
115 gpm
435 lpm
22