background image

Warnings

312358F

7

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system com-
ponent. See Technical Data in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all 
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information 
about your material, request Safety Data Sheet (SDS) from distributor or retailer.

Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-
facturer’s replacement parts only.

Do not alter or modify equipment. Alterations or modifications may void agency approvals and create 
safety hazards.

Make sure all equipment is rated and approved for the environment in which you are using it.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

MOVING PARTS HAZARD

Moving parts can pinch, cut or amputate fingers and other body parts.

Keep clear of moving parts.

Do not operate equipment with protective guards or covers removed.

Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, 
follow the Pressure Relief Procedure and disconnect all power sources.

TOXIC FLUID OR FUMES HAZARD

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or 
swallowed.

Read Safety Data Sheet (SDS) to know the specific hazards of the fluids you are using.

Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.

PERSONAL PROTECTIVE EQUIPMENT

Wear appropriate protective equipment when in the work area to help prevent serious injury, including 
eye injury, hearing loss, inhalation of toxic fumes, and burns. Protective equipment includes but is not 
limited to:

Protective eyewear, and hearing protection. 

Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.

Summary of Contents for High-Flo 703558

Page 1: ...nformation including maximum working pressure Important Safety Instructions Read all warnings and instructions in this manual Save these instructions TI10362A TI10364A Xtreme Packages High Flo Package...

Page 2: ...treme Packages 13 Dura Flo Packages 14 Suction Kits for Dura Flo Packages 15 Filter Kits for Dura Flo Packages 16 High Flo Packages 17 Mounting Hole Diagram 18 Dimensions 19 Graco Standard Warranty 20...

Page 3: ...wet cup and npt connec tions N To order replacement parts see Parts starting on page 12 ID TI10428A 1 16 M C N First Digit Second and Third Digit Fourth Digit Fifth Digit Sixth Digit Pump Type Pressu...

Page 4: ...4 164 100 0 7 7 0 290 130MCN 3150 21 7 217 100 0 7 7 0 220 230MCN 3150 21 7 217 100 0 7 7 0 220 330MCN 3150 21 7 217 100 0 7 7 0 220 Part No Maximum Working Pressure psi MPa bar Maximum Air Input Pres...

Page 5: ...703SS0 300 2 1 21 100 0 7 7 0 1500 704MS8 400 2 8 28 100 0 7 7 0 1000 704MS9 400 2 8 28 100 0 7 7 0 1000 704MS0 400 2 8 28 100 0 7 7 0 1000 704SS8 400 2 8 28 100 0 7 7 0 1000 704SS9 400 2 8 28 100 0 7...

Page 6: ...oses Hold gun firmly to side of grounded pail when triggering into pail Do not use pail liners unless they are anti static or conductive Stop operation immediately if static sparking occurs or you fee...

Page 7: ...ute hoses and cables away from traffic areas sharp edges moving parts and hot surfaces Do not kink or over bend hoses or use hoses to pull equipment Keep children and animals away from work area Compl...

Page 8: ...ound Air and fluid hoses use only electrically conductive hoses Air compressor follow manufacturer s recommenda tions Spray gun Dispense valve ground through connec tion to a properly grounded fluid h...

Page 9: ...ne moisture drain valve S install at the bot tom of each air line drop to drain moisture Fluid Line Components Some Xtreme and Dura Flo packages include fluid suc tion kits and fluid filter kits See p...

Page 10: ...e H Air Filter hidden J Fluid Filter K Fluid Drain Valve required L 55 Gallon 200 Liter Drum Suction Kit M 5 Gallon 19 Liter Pail Suction Kit N Pump Ground Wire required P Main Air Supply Line R Air L...

Page 11: ...nt For complete instructions and warnings see your respective pump manual See Related Manuals page 2 This equipment stays pressurized until pressure is manually relieved To help prevent serious injury...

Page 12: ...1 3 255143 BRACKET mounting includes 4 and 5 1 4 100101 SCREW mounting cap hex head 3 8 16 x 1 in 25 mm 4 5 100133 WASHER lock 3 8 4 6 244524 WIRE ground 1 Xtreme Package Reference Number and Descrip...

Page 13: ...npt fbe 1 102 116402 ADAPTER quick connect 1 103 206266 TUBE suction see 306938 1 104 247302 HOSE suction 1 in npt m x quick connect 10 ft 3 05 m 1 105 100474 COUPLING pipe 1 in npt fbe 1 106 158555 N...

Page 14: ...nting includes 4 and 5 1 4 100101 SCREW mounting cap hex head 3 8 16 x 1 in 25 mm 4 5 100133 WASHER lock 3 8 4 6 244524 WIRE ground 1 Dura Flo Package Reference Number and Description 1 7 8 100 200 Pu...

Page 15: ...22 ADAPTER 1 1 2 sanitary x 1 1 2 npt 1 105 120351 GASKET sanitary 1 106 118598 CLAMP sanitary 1 5 in 1 Ref Part Description Qty 101 15M668 ADAPTER 2 npt m x 3 4 npt f 1 102 15M666 ELBOW 3 4 npt m x f...

Page 16: ...npt m x 3 8 npsm m 1 206 238967 VALVE ball 3 8 npt mbe see 306861 1 207 223160 FILTER fluid see 307273 1 Ref Part Description Qty 201 102281 BUSHING 3 4 npt m x 3 8 npt f 1 202 15C076 ADAPTER 3 8 npt...

Page 17: ...Ref Part Description Qty 2 NXT011 CONTROL air integrated see 311239 1 3 255143 BRACKET mounting includes 4 and 5 1 4 100101 SCREW mounting cap hex head 3 8 16 x 1 in 25 mm 4 5 100133 WASHER lock 3 8...

Page 18: ...in 368 mm C 12 4 in 314 mm D 9 0 in 229 mm E 5 4 in 137 mm F 7 4 in 187 mm G 5 3 in 133 mm H 2 0 in 51 mm J 1 0 in 25 mm K 1 6 in 41 mm L 2 7 in 69 mm M 4 4 in 112 mm N Four 0 562 in 14 mm diameter ho...

Page 19: ...5 gal 40 7 1033 13 8 350 0 9 22 42 3 1074 3 4 npt f 1 1 2 npt m 3 8 npt f 153 2 69 Dura Flo Pumps bare 43 4 1102 13 8 350 n a n a 3 4 npt f 2 npt f 1 npt f 101 4 45 Dura Flo Pumps 5 gal 43 4 1102 13 8...

Page 20: ...inspection of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation T...