background image

Warnings 

6

312358F

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When 
these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific 
hazard symbols and warnings not covered in this section may appear throughout the body of this manual where 
applicable.

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. Paint or solvent 
flowing through the equipment can cause static sparking. To help prevent fire and explosion:

Use equipment only in well ventilated area.

Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop 
cloths (potential static sparking). 

Ground all equipment in the work area. See Grounding instructions.

Never spray or flush solvent at high pressure.

Keep work area free of debris, including solvent, rags and gasoline.

Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes 
are present.

Use only grounded hoses.

Hold gun firmly to side of grounded pail when triggering into pail. Do not use pail liners unless they 
are anti-static or conductive.

Stop operation immediately if static sparking occurs or you feel a shock. Do not use equipment until 
you identify and correct the problem.If there is static sparking or you feel a shock, stop operation 
immediately.
 Do not use equipment until you identify and correct the problem. 

Static charge may build up on plastic parts during cleaning and could discharge and ignite flammable 
vapors. To help prevent fire and explosion:

Clean plastic parts only in a well ventilated area.

Do not clean with a dry cloth.

Keep a working fire extinguisher in the work area.

SKIN INJECTION HAZARD 

High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This 
may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical 
treatment.

Engage trigger lock when not dispensing.

Do not point dispensing device at anyone or at any part of the body.

Do not put your hand over the fluid outlet.

Do not stop or deflect leaks with your hand, body, glove, or rag.

Follow the Pressure Relief Procedure when you stop dispensing and before cleaning, checking, or 
servicing equipment. 

Tighten all fluid connections before operating the equipment.

Check hoses and couplings daily. Replace worn or damaged parts immediately.

Summary of Contents for High-Flo 703558

Page 1: ...nformation including maximum working pressure Important Safety Instructions Read all warnings and instructions in this manual Save these instructions TI10362A TI10364A Xtreme Packages High Flo Package...

Page 2: ...treme Packages 13 Dura Flo Packages 14 Suction Kits for Dura Flo Packages 15 Filter Kits for Dura Flo Packages 16 High Flo Packages 17 Mounting Hole Diagram 18 Dimensions 19 Graco Standard Warranty 20...

Page 3: ...wet cup and npt connec tions N To order replacement parts see Parts starting on page 12 ID TI10428A 1 16 M C N First Digit Second and Third Digit Fourth Digit Fifth Digit Sixth Digit Pump Type Pressu...

Page 4: ...4 164 100 0 7 7 0 290 130MCN 3150 21 7 217 100 0 7 7 0 220 230MCN 3150 21 7 217 100 0 7 7 0 220 330MCN 3150 21 7 217 100 0 7 7 0 220 Part No Maximum Working Pressure psi MPa bar Maximum Air Input Pres...

Page 5: ...703SS0 300 2 1 21 100 0 7 7 0 1500 704MS8 400 2 8 28 100 0 7 7 0 1000 704MS9 400 2 8 28 100 0 7 7 0 1000 704MS0 400 2 8 28 100 0 7 7 0 1000 704SS8 400 2 8 28 100 0 7 7 0 1000 704SS9 400 2 8 28 100 0 7...

Page 6: ...oses Hold gun firmly to side of grounded pail when triggering into pail Do not use pail liners unless they are anti static or conductive Stop operation immediately if static sparking occurs or you fee...

Page 7: ...ute hoses and cables away from traffic areas sharp edges moving parts and hot surfaces Do not kink or over bend hoses or use hoses to pull equipment Keep children and animals away from work area Compl...

Page 8: ...ound Air and fluid hoses use only electrically conductive hoses Air compressor follow manufacturer s recommenda tions Spray gun Dispense valve ground through connec tion to a properly grounded fluid h...

Page 9: ...ne moisture drain valve S install at the bot tom of each air line drop to drain moisture Fluid Line Components Some Xtreme and Dura Flo packages include fluid suc tion kits and fluid filter kits See p...

Page 10: ...e H Air Filter hidden J Fluid Filter K Fluid Drain Valve required L 55 Gallon 200 Liter Drum Suction Kit M 5 Gallon 19 Liter Pail Suction Kit N Pump Ground Wire required P Main Air Supply Line R Air L...

Page 11: ...nt For complete instructions and warnings see your respective pump manual See Related Manuals page 2 This equipment stays pressurized until pressure is manually relieved To help prevent serious injury...

Page 12: ...1 3 255143 BRACKET mounting includes 4 and 5 1 4 100101 SCREW mounting cap hex head 3 8 16 x 1 in 25 mm 4 5 100133 WASHER lock 3 8 4 6 244524 WIRE ground 1 Xtreme Package Reference Number and Descrip...

Page 13: ...npt fbe 1 102 116402 ADAPTER quick connect 1 103 206266 TUBE suction see 306938 1 104 247302 HOSE suction 1 in npt m x quick connect 10 ft 3 05 m 1 105 100474 COUPLING pipe 1 in npt fbe 1 106 158555 N...

Page 14: ...nting includes 4 and 5 1 4 100101 SCREW mounting cap hex head 3 8 16 x 1 in 25 mm 4 5 100133 WASHER lock 3 8 4 6 244524 WIRE ground 1 Dura Flo Package Reference Number and Description 1 7 8 100 200 Pu...

Page 15: ...22 ADAPTER 1 1 2 sanitary x 1 1 2 npt 1 105 120351 GASKET sanitary 1 106 118598 CLAMP sanitary 1 5 in 1 Ref Part Description Qty 101 15M668 ADAPTER 2 npt m x 3 4 npt f 1 102 15M666 ELBOW 3 4 npt m x f...

Page 16: ...npt m x 3 8 npsm m 1 206 238967 VALVE ball 3 8 npt mbe see 306861 1 207 223160 FILTER fluid see 307273 1 Ref Part Description Qty 201 102281 BUSHING 3 4 npt m x 3 8 npt f 1 202 15C076 ADAPTER 3 8 npt...

Page 17: ...Ref Part Description Qty 2 NXT011 CONTROL air integrated see 311239 1 3 255143 BRACKET mounting includes 4 and 5 1 4 100101 SCREW mounting cap hex head 3 8 16 x 1 in 25 mm 4 5 100133 WASHER lock 3 8...

Page 18: ...in 368 mm C 12 4 in 314 mm D 9 0 in 229 mm E 5 4 in 137 mm F 7 4 in 187 mm G 5 3 in 133 mm H 2 0 in 51 mm J 1 0 in 25 mm K 1 6 in 41 mm L 2 7 in 69 mm M 4 4 in 112 mm N Four 0 562 in 14 mm diameter ho...

Page 19: ...5 gal 40 7 1033 13 8 350 0 9 22 42 3 1074 3 4 npt f 1 1 2 npt m 3 8 npt f 153 2 69 Dura Flo Pumps bare 43 4 1102 13 8 350 n a n a 3 4 npt f 2 npt f 1 npt f 101 4 45 Dura Flo Pumps 5 gal 43 4 1102 13 8...

Page 20: ...inspection of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation T...

Reviews: