Troubleshooting
36
3A5578C
E34: Up Button Error
The Up Button or Handlebar Rocker Switch is stuck or shorted.
Disconnect Handlebar Rocker Switch from the DCS
Control. Clear the error code.
If the error code reappears 30 seconds after turn-
ing the Power Switch back ON, the problem is the
Up Button on the DCS Control. Check to see if the
Up Button is stuck. If not stuck, replace the Up
Button Switch.
If the error code does not reappear 30 seconds
after turning the Power Switch back ON, the prob-
lem is the Handlebar Rocker Switch. Check to see
if the switch is stuck. If not stuck, replace the Han-
dlebar Rocker Switch.
E35: Down Button Error
The Down Button or Handlebar Switch is stuck or shorted.
Disconnect Handlebar Rocker Switch from the DCS
Control. Clear the error code.
If the error code reappears 30 seconds after turn-
ing the Power Switch back ON, the problem is the
Down Button on the DCS Control. Check to see if
the Down Button is stuck. If not stuck, replace the
Down Button Switch.
If the error code does not reappear 30 seconds
after turning the Power Switch back ON, the prob-
lem is the Handlebar Rocker Switch. Check to see
if the switch is stuck. If not stuck, replace the Han-
dlebar Rocker Switch.
Error
Cause
Solution