background image

SPRAYING

Turn safety lever 
of gun to OFF.

Point gun at area to be sprayed about 30 cm from surface, and begin moving gun before triggering. A good spray pattern is evenly distributed as it hits surface.
Set pressure just high enough to spray without heavy edges. Use smaller tip size for thinner material and a larger tip size for thicker material if pressure adjust-
ment cannot achieve even spray pattern.

SHUTDOWN AND CLEANUP 

* for AutoClean

2

: see bottom of this page

Set power
switch to OFF.

Trigger gun 
until pressure 
is relieved.

Turn prime valve to
Prime position
(down).

Remove gun filter
assembly.

Unscrew tip & guard from
gun. Clean gun filter, inlet
screen, tip, guard and 
manifold filter with water 
and brush.

Set power switch to ON,
and increase pressure 
until sprayer starts.

As soon as Pump Armor
comes out of drain tube,
set power switch to OFF.

Screw inlet screen onto siphon
tube, replace manifold filter and
spacer, and assemble gun with
filter, tip and guard.

Wipe outside of sprayer,
hose and gun with rag soaked
in water or mineral spirits.

Fill throat packing nut
with TSL

Place drain tube
and siphon tube 
in pail of water.

Turn pressure control knob to low-
est setting, set power switch to
ON, and increase pressure until
sprayer starts. Let sprayer run and
flush itself for 2 minutes.

Keeping gun triggered 
into water pail, turn prime
valve to Spray position
(horizontal).

Set power switch to OFF, turn 
pressure control knob to lowest 
setting, and turn prime valve to
Prime position (down).

Place drain tube in waste pail
and siphon tube in 
container of Pump Armor

Assemble gun 
without filter.

Unscrew inlet screen
from siphon tube.

Keep gun triggered
into pail for 1 minute,
until water coming out
of gun is clean.

Remove manifold 
filter and spacer.

Remove suction and drain tubes from
paint. Place drain tube into waste pail
and wipe suction tube clean.

Place suction tube in 
appropriate cleaning fluid.

Close drain valve.
Switch power ON.

To save paint from hose and pump,
trigger gun into paint pail and increase
pressure. When cleaning fluid appears,
release gun trigger.

Turn pressure all the way down.
Open drain valve.

 

 

 

 

 

 

Screw connector
onto gun.

Rotate trigger lock
clip 90° to lock 
trigger open.

Press display button 
until timer appears and turn 
pressure control knob to highest.

Close drain valve.

With clean fluid, briefly trigger gun 
into waste pail several times to
clear any debris from front of gun.

Install tip and guard and briefly trigger 
gun into waiste pail to clean tip.
Reverse tip if necessary.

GRACO N.V.

Industrieterrein Oude Bunders

Slakweidestraat 31 • B-3630 Maasmechelen
Tel: +32 (89) 770 700 • Fax: +32 (89) 770 777
E-mail: [email protected] • http://www.graco.be

All information, illustrations, and specifications in this document are based on the latest product information

available at the time of publication. The right is reserved to make changes at any time without notice.

© 2002, 2006  Graco N.V. · Form No. 328009 E (rev.C) · 01/08 · Printed in Europe.

Graco is certified ISO 9001.

Place gun in 
AutoClean connector.

Slide open end 
over back of handle.

AUTOCLEAN

2

GUIDE

When finished, remove 
trigger clip from gun handle.

Unscrew connector from gun.
Remove gun from connector.

All manuals and user guides at all-guides.com

Reviews: