311493A
7
Using Direct Immersion
1.
Apply pipe thread sealant (25) over male threads on
pump.
2.
Attach female camlock (22) from kit over male
threads on pump. Tighten securely.
3.
Position 55 gallon drum under pump assembly.
4.
Unclamp and tilt tower/bracket back to first position.
5.
Lock clamp into 1st position.
6.
Install strainer (23) to bottom of intake tube (24).
MOVING PARTS HAZARD
Moving parts can pinch or amputate fingers and other
body parts.
•
Keep clear of moving parts.
•
Do not operate equipment with protective guards
or covers removed.
•
Pressurized equipment can start without warning.
Before checking, moving, or servicing equipment,
follow the
Pressure Relief Procedure
in this man-
ual. Disconnect power or air supply.
apply
sealant
pump
22
pump
assembly
drum
clamp