background image

311493A

7

Using Direct Immersion 

1.

Apply pipe thread sealant (25) over male threads on 
pump.

2.

Attach female camlock (22) from kit over male 
threads on pump. Tighten securely.

3.

Position 55 gallon drum under pump assembly.

4.

Unclamp and tilt tower/bracket back to first position.

5.

Lock clamp into 1st position.

6.

Install strainer (23) to bottom of intake tube (24).

MOVING PARTS HAZARD 

Moving parts can pinch or amputate fingers and other 
body parts.

Keep clear of moving parts.

Do not operate equipment with protective guards 
or covers removed.

Pressurized equipment can start without warning. 
Before checking, moving, or servicing equipment, 
follow the 

Pressure Relief Procedure

 in this man-

ual. Disconnect power or air supply.

apply 
sealant

pump

22

pump
assembly

drum

clamp

1st position

Summary of Contents for GH 833

Page 1: ...structions GH833 Direct Immersion Kit For installation of tower bracket Part No 287843 Refer to GH833 operation manual Before attempting to install kit follow Pressure Relief Procedure page 4 Importan...

Page 2: ...llips screwdriver remove the handle sleeve screws 4 2 Remove handle assembly by pulling it out of upper frame handle tubes 3 Remove frame tube plugs 2 located behind the wheels 4 Insert plugs in upper...

Page 3: ...ndle steps 1 5 page 2 2 Place U bolts over sprayer frame and through holes in vehicle bed Place a washer and nut over bolt end Using a wrench tighten nut securely Sprayer is a heavy piece of equipment...

Page 4: ...Set pump valve OFF 3 Turn engine OFF 4 Turn pressure to lowest setting 5 Trigger gun to relieve pressure 6 Turn Prime valve down Trigger Lock Always engage the trigger lock when you stop spraying to p...

Page 5: ...olts on pump assembly and set assembly out of the way 6 Remove 2 black plugs NOTE Protect open hydraulic ports from debris and contamination BURN HAZARD Equipment surfaces and fluid that s heated can...

Page 6: ...3 ft lbs 5 Install new longer hydraulic lines 19 20 from kit 6 To purge air from hydraulic lines increase pressure enough to start hydraulic motor stroking and allow fluid to circulate for 15 seconds...

Page 7: ...into 1st position 6 Install strainer 23 to bottom of intake tube 24 MOVING PARTS HAZARD Moving parts can pinch or amputate fingers and other body parts Keep clear of moving parts Do not operate equip...

Page 8: ...o hold tube securely in place 8 Lower tube into 55 gallon drum 9 Lock tower bracket in place 10 Ready to use Changing Drums 1 Tilt tower bracket back and clamp securely in first position 2 Unlock caml...

Page 9: ...and align new drum under pump assembly 4 Install intake tube 24 Lock camlocks 22 to hold tube securely in place 5 Lower tube into 55 gallon drum 6 Lock tower bracket in place 7 Ready to use 22 24 pum...

Page 10: ...t back 90 to 2nd position for transporting 3 Lock in place CAUTION Do not transport unit with head in vertical position When transporting unit securely tie down in vehicle or follow instructions for f...

Page 11: ...W shoulder 3 10 100023 WASHER flat 4 11 15H496 LATCH liftkit lower 1 12 15H495 LATCH liftkit upper 1 13 120226 SCREW hex hd flange 4 14 108063 GRIP handle 1 15 114808 CAP vinyl 1 16 195550 LATCH adjus...

Page 12: ...of publication Graco reserves the right to make changes at any time without notice MM 311493 Graco Headquarters Minneapolis International Offices Belgium China Japan Korea GRACO INC P O BOX 1441 MINN...