Installing Direct Immersion Kit
1.
Install tower/bracket into frame holes.
2.
Install (4) retaining screws in frame to hold
tower/bracket in place. Torque to 165 +/- 10 in.-lbs
(13.8 ft.-lbs).
3.
Install pump assembly over (4) frame bolts.
4.
Torque bolts to 400 +/- 10 in-lbs (33.3 ft. lbs).
5.
Install new, longer hydraulic lines (19, 20) from kit.
6.
To purge air from hydraulic lines, increase pressure
enough to start hydraulic motor stroking and allow
fluid to circulate for 15 seconds. Turn pressure
down, turn prime valve horizontal (Off).
Pumping motion could result in bracket pulling out of
frame and cause serious injury. Always insert and
torque screws securely to insure this does not occur.