![Graco Geo Blaster GB1200 Operation And Parts Download Page 18](http://html1.mh-extra.com/html/graco/geo-blaster-gb1200/geo-blaster-gb1200_operation-and-parts_2252667018.webp)
Operation
18
3A4167C
Shutdown
1.
When you have finished blasting, perform wash until
all of the abrasive is flushed from the blast hose.
See “Wash Down” on page 17.
2.
Turn the selector valve (K) to OFF, and with the
abrasive valve (P) closed, continue to blast until
water is cleared from the hose. This is to dry the
inside of the hose for storage.
3.
Perform “Pressure Relief Procedure” on page 10.
NOTICE
During cold weather, use glycol to protect the pump
and prevent it from freezing.