![Graco Geo Blaster GB1200 Operation And Parts Download Page 12](http://html1.mh-extra.com/html/graco/geo-blaster-gb1200/geo-blaster-gb1200_operation-and-parts_2252667012.webp)
Operation
12
3A4167C
Setting Up the Equipment
1.
Shut the water tank drain valve (Q). Fill tank with
water or connect to water supply.
2.
Push E-stop (M) down.
3.
Turn selector valve (K) to Off position.
4.
Connect blast hose, hose restraints, control hoses
and coupler pins.
5.
Connect air supply hose from compressor. Turn on
air compressor.
Air supply requirements:
•
GB400 and GB600: minimum,185 cfm;
maximum = 900 cfm
•
GB1200: minimum 600 cfm;
maximum = 1600 cfm
6.
Ensure safety whip checks are installed on air and
blast hoses.
7.
Check air inlet pressure. Minimum pressure = 110
psi; maximum = 150 psi.
8.
Push down plunger and lock.
NOTICE
Be sure the tank does not run dry during blasting, as
this will damage the water pump.
Summary of Contents for Geo Blaster GB1200
Page 25: ...Parts 3A4167C 25 Control Panel Components upper left...
Page 27: ...Parts 3A4167C 27 Control Panel Components lower left...
Page 29: ...Parts 3A4167C 29 Control Panel Components lower right...
Page 31: ...Parts 3A4167C 31 Control Panel Components upper right Rear View of Item 48...
Page 33: ...Parts 3A4167C 33 Control Panel Components rear...
Page 35: ...Parts 3A4167C 35 Water Valve and Pressure Relief Valve Components...
Page 37: ...Parts 3A4167C 37 Air Valve Components...
Page 39: ...Parts 3A4167C 39 Water Valve and Filter Components...
Page 42: ...Parts 42 3A4167C Water Pump Components...
Page 53: ...Technical Data 3A4167C 53...