Advanced Programming
3A4676B
29
Models with Firmware 6.03 and
Later
A10 - Low Level Reset Upon Power On
This function changes the behavior of the low level upon
pump power on. When A10 is on, a low level fault clears
when the pump power is cycled. The pump will revolve 5
revolutions, checking to see if the low level condition is
still present. If not, it will self clear and continue. If a low
level condition exists during the 5 revolutions, it will go
into a low level fault.
Low Level ON LED illuminates (F
1.
The default OFF is displayed. The
alarm output will toggle once a
second.
2.
Press the UP or DOWN
ARROW button to change
OFF to ON on the display to
change the low level reset
upon power on.
3.
Press the ENTER button.
A11- Warning Off Through Alarm Relay
This function changes the behavior of the alarm output
in a warning condition to always off.
Fault and Warning LEDs Illuminate
1.
The default OFF is
displayed. The alarm
output will turn on
during a warning
condition.
2.
Press the UP or DOWN
ARROW to change OFF to
ON on the display to change
the alarm output to be off
during a warning condition.
3.
Press the ENTER button to exit
Advanced Programming.
4.