Installation
12
332305B
Alarm Output and Remote Illumination Response
The following tables include graphical representations of the connector as it appears on the unit, a pin-out associated
with the connector and a typical installation wiring diagram. An internal representative wiring diagram is included
where it is deemed useful.
Wire colors provided on these pages only refer to the power cable provided by Graco with this product.
Alarm Relay Response
Alarm Output
Standard Remote
Illumination
(via 5 wire CPC power
cable)
Tri-Color Remote
Illumination
(via illuminated manual run
input)
Unit in OFF Mode
Deactivated (off)
Off
Off
Unit in ON Mode
Deactivated (off)
On
Green
Warning Condition
Activated (on)
Toggles On and Off once
per second
Yellow
Fault Condition
Toggles On and Off
once per second
Toggles On and Off once
per second
Red
Fault Condition
(Advanced Programming
Setting A7 OFF)
Toggles On and Off
once per second
Toggles On and Off once
per second
Red
Fault Condition
(Advanced Programming
Setting A7 ON)
Activated (on)
Toggles On and Off once
per second
Red
Output Tied to Common
No Faults or
Warnings
Warning
Fault
(Advanced
Programming A7
OFF)
Fault
(Advanced
Programming
Setting A7 ON)
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
1 second
N.O.
N.C.