2

307942D

Installation

Pressure Relief Procedure

PRESSURIZED FLUID HAZARD

The equipment stays pressurized until
pressure is manually relieved.  To re-
duce the risk of serious injury from

pressurized fluid, accidental spray from the valve,
or splashing fluid, follow this procedure whenever
you

D

Are instructed to relieve pressure

D

Stop dispensing

D

Check, clean, or service any system equipment

D

Install or clean dispensing devices

WARNING

NOTE:

Reference numbers and letters in parentheses

in the text refer to the Parts Drawing on page 3.

MOVING PARTS HAZARD

Never

 

operate the pump with the warn-

ing plate (1) or the identification plate (2)
removed.  These plates protect your

fingers from getting pinched or amputated by
moving parts in the air motor.

WARNING

Replace the Muffler Plates

NOTE:

You cannot order parts or request service or

warranty information without the serial label
information. Record the serial label (A) information on
the front of this manual as an added precaution. Keep
the manual in a safe place.

1.

Unscrew the plate retaining screws and remove
the identification muffler plate and warning muffler
plate from both sides of the air motor. To avoid
twisting the screw heads off if the screws are hard
to remove, tap lightly on the screw heads with a
hammer, then remove them.

2.

Discard the old identification muffler plate and
warning muffler plate. The muffler kit includes an
identification plate for one side and a warning plate
for the other side.

3.

Install the two mufflers (1, 2) on the air motor as
shown on the Parts Drawing. Fasten the mufflers
to the air motor, using the plate retaining screws
(3).

4.

With the air motor operating, check all around both
mufflers for air leaks. Adjust the plate retaining
screws if necessary.

Summary of Contents for FIRE–BALL 300 Air Motor Muffler Kit

Page 1: ...307942D GRACO PUMP PART NO SERIAL MAX AIR WPR MAX FLUID WPR SERIES MPA bar psi MPA bar psi IMPORTANT You cannot order parts or request service and warranty information for the complete pump without the information on the serial label Record all the information from the serial label in these spaces Keep this manual in a safe place as an extra precaution Read warnings and instructions ...

Page 2: ... Muffler Plates NOTE You cannot order parts or request service or warranty information without the serial label information Record the serial label A information on the front of this manual as an added precaution Keep the manual in a safe place 1 Unscrew the plate retaining screws and remove the identification muffler plate and warning muffler plate from both sides of the air motor To avoid twisti...

Page 3: ...3 Parts REF PART DESCRIPTION QTY NO NO 1 234577 MUFFLER identification and serial plate side 1 2 234578 MUFFLER warning plate side 1 3 100078 SCREWS plate retaining No 8 32 x 0 375 in 12 A Serial label 1 2 3 A ...

Page 4: ...shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be brought within two 2 years of the date of sale Graco makes no warranty and disclaims all implied warranti...

Reviews: