14
334730F
11. Place fluid intake with drain tube in
grounded metal pail partially filled with
flushing fluid. See
12. Turn pressure control to lowest setting.
13. Set SELECTOR switch to
AIRLESS
position.
14. Turn prime valve horizontal. Disengage
trigger lock.
15. Increase pressure 1/2 turn to start motor.
16. Hold a metal part of the gun firmly to a
grounded metal pail. Trigger gun and
flush for one minute.
17. Set SELECTOR switch to
OFF
position.
18. Engage trigger lock.
19. After flushing storage fluid out of the
sprayer empty pail. Replace fluid intake
with drain tube in grounded metal pail
partially filled with flushing fluid. Use
water to flush water-based paint or
mineral spirits to flush oil-based paint.
20. Set SELECTOR switch to
AIRLESS
position.
21. Turn prime valve horizontal. Disengage
trigger lock.
22. Hold a metal part of the gun firmly to a
grounded metal pail. Trigger gun and
flush until clean.
23. Set SELECTOR switch to
OFF
position.
24. Engage trigger lock.
25. Sprayer is now ready to startup and
spray in airless mode.
26. Attach air hose to sprayer air hose
connection.
27. Cut air hose to length and couple to air
connection on gun.
28. Sprayer is now ready to startup and
spray in air-assisted (AA) mode.
NOTE:
New sprayers are shipped with
storage fluid that must be flushed out with
mineral spirits prior to using the sprayer.
Check flushing fluid for compatibility with
material that is to be sprayed. A secondary
flush with a compatible fluid may be
necessary. Use water for latex paint or
mineral spirits for oil-based paint.
ti24640a
ti25452a