Operation
334730F
19
7.
Trigger gun. While spraying, turn air
regulator knob to increase pressure until
tails disappear.
8.
Use gun air regulator to fine tune spray
pattern.
Airless Spraying
1.
Set SELECTOR switch to
AIRLESS
position.
2.
Prime pump, see
3.
Start with pressure turned to the lowest
setting. Spray test pattern. Gradually
increase fluid pressure until you achieve
a consistent spray pattern without heavy
edges. Use a smaller tip size if pressure
adjustment alone does not eliminate
heavy edges.
•
Hold gun perpendicular and 10-12
inches from the surface. Overlap
strokes by 50%.
•
Move gun before triggering and
release trigger before stopping.
ti25547a
ti25546a
ti25482a
ti25539a