Symptoms:
•
Sprayer does not run at all
E=06
•
Digital Display shows E=06
•
Control board status light blinks 6x repeatedly.
What does this mean?
Motor is too hot or motor thermal switch connections are likely the problem.
Troubleshooting Procedure:
1. Check thermal switch and connections to control board. Set sprayer to OFF
and
disconnect power to sprayer
.
2. Disconnect motor thermal switch wires from control board. Check that all
connections at the control board are clean and secure.
3. If connections are all OK, allow sprayer to cool. If sprayer runs when cool,
correct cause of overheating. Keep sprayer in cooler location with good
ventilation. Make sure motor air intake is not blocked. If sprayer still doesn’t
run go to step 4.
4. See Airless Motor Test procdure for the appropriate motor.
33