Calibration
Calibration
Calibration Procedure
Procedure
Procedure
NOTICE
NOTICE
NOTICE
To prevent damage to the heated hose, a hose
calibration is required if any of the following
conditions are true:
• The hose has never been calibrated before.
• A section of hose has been replaced.
• A section of hose has been added.
• A section of hose has been removed.
NOTE:
NOTE:
NOTE: The Reactor and heated hose must be at
the same ambient temperature to get the most
accurate calibration.
1. Enter Setup Mode and navigate to System
screen 3, then press the Calibrate soft key
.
2. Press the Continue soft key
to
acknowledge the reminder to have the hose
at ambient conditions.
3. Wait while the system measures the hose
resistance.
NOTE:
NOTE:
NOTE: If hose heat was on prior to the
calibration procedure, the system will
wait up to five minutes to allow the wire
temperature to equalize.
NOTE:
NOTE:
NOTE: The hose temperature must be above
32 °F (0 °C) during calibration.