Error
Error
Error
Location
Location
Location
Type
Type
Type
Description
Description
Description
Cause
Cause
Cause
Solution
Solution
Solution
Module does not
have software
Insert a system token
into the ADM module
and cycle the power.
Wait until the upload
is complete before
removing the token.
No 24 VDC
supply to module
Green light on each
module should be lit.
If green light is not lit,
check to make sure each
CAN cable connection is
tight. Verify the power
supply is outputting 24
VDC. If not, check power
supply wiring. If wiring is
okay, replace the power
supply.
CACT
TCM
TCM Communica-
tion Error
Loose or broken
CAN cable
Check the CAN cables
running between GCA
modules and tighten of
needed. If the problem
still persists move
each cable around the
connector and watch the
flashing yellow light on
the GCA modules.
If
the yellow light stops
flashing, replace the CAN
cable.
Mix chamber too large
for system selected. Use
mix chamber rated for
system.
Ensure the system has
chemical and the feed
pumps are operating
correctly.
No material in pumps.
Verify pumps are
supplying chemical.
If necessary, replace or
refill drums.
DADX
HCM
Pump Runaway
Flow rate is too
large
Inlet ball valves are
closed. Open ball valves.
ISO Inlet pressure
is too low
Increase ISO feed pump
pressure.
F9FA
ADM
Flow Cutback Low
Inlet A Pressure
ISO inlet flow is
too low
Change to larger ISO feed
pump.