Disassemble the Fluid Section
1. Stop the pump. Follow the
Pressure Relief Procedure, page 13
.
2. Use a hex socket wrench (6 mm for 4D150
models; 8 mm for 4D350 models) to remove the
inlet and outlet fluid manifold bolts (16). Remove
the fluid manifolds (2).
3. Remove the check valve cartridges (9).
4. Do not remove the manifold o-rings (38) yet.
5. Use a hex socket wrench (6 mm for 4D150
models; 8 mm for 4D350 models) to remove the
bolts (15) from one fluid cover (4). Remove the
fluid cover.
Fluid Section Disassembly or Reassembly
Included in Fluid Section Fastener Kit 17H325.
333015E