Electric Motor
16
311592Z
Electric Motor
Electric Motor Specifications
The electric motor must be approved as explosion-proof
for use in a hazardous area. See
Approvals
, page 5, for
applicable agencies and requirements. All wiring must
meet Local and National electric codes for hazardous
area.
See T
ABLE
4 for motor specifications. If motor is not pur-
chased with pump, adapter kits are available. See T
ABLE
5 on page 17.
NOTE:
Graco does not support the use of the Graco
VFD CAM mode on motors not supplied by Graco.
Motor Wiring
See the
System Wiring Schematics
on pages 10 and
11.
Install an explosion-proof seal fitting in the wall separat-
ing the hazardous area from the non-hazardous area.
Use explosion-proof conduit or increased safety protec-
tion concepts to run wires between the motor junction
box and the variable frequency drive (VFD).
Use 14 gauge wire (3 wires plus ground) to connect the
VFD and the motor.
Use 18 gauge wire between pins 8 and 11 on the VFD
and the motor overtemperature switch.
Motor must be wired to rotate fan counter-clockwise
when viewed from fan end of motor. See F
IG
. 9 or F
IG
.
10.
Improper wiring may cause electric shock or other
serious injury if work is not performed properly. Have
a qualified electrician perform any electrical work. Be
sure your installation complies with all National,
State and Local safety and fire codes.
Table 4: Electric Motor Specifications
Motor Kit
Part No.
Voltage
Phase
Supply
Frequency
Horsepower
rpm
Full Load
Torque
255226
230/400V
3
50 Hz
5
1500
(4 pole)
15 ft-lb
(20.3 N•m)
255225
230/460V
3
60 Hz
5
1800
(4 pole)
15 ft-lb
(20.3 N•m)
289552
230/400V
3
50 Hz
3
1500
(4 pole)
9.1 ft-lb
(12.3 N•m)
289551
230/460V
3
60 Hz
3
1800
(4 pole)
9.1 ft-lb
(12.3 N•m)
NOTE:
The motor must be rated for use with a VFD. The motor must be able to operate at full
current through the range of 5-50 Hz or 6-60 Hz.