Integration
333587B
71
Communications Gateway Module (CGM)
Overview
The Communications Gateway Module (CGM) provides
a control link between the E-Flo iQ system and a
selected fieldbus. This provides the means for report
monitoring and control by external automation systems.
NOTE:
The following system network configuration files
are available at
help.graco.com.
•
EDS file: DeviceNet or EtherNet/IP fieldbus
networks
•
GSD file: PROFIBUS fieldbus networks
•
GSDML: PROFINET fieldbus networks
NOTE:
See the Supply System Communications
Gateway Module Installation Kit manual for CGM
installation. See
Related Manuals
on page
E-Flo iQ and PLC Connection Setup
Verify that the PLC parameters are set up correctly, see
the Gateway Map table.
NOTE:
If the PLC connection parameters are not setup
correctly, the connection between the E-Flo iQ and PLC
will not be made.
Available Internal Data
Unless stated otherwise, bytes are stored in each
instance in little endian order (byte order within instance:
most significant to least significant).
NOTE:
Automation Outputs can be monitored by the
corresponding Automation Inputs to verify that the E-Flo
iQ received the data.
See the
Automation Outputs
and the
Automation Inputs
on page
.
Gateway Map: 18A925 for E-Flo iQ Ram
Map name: E-Flo_iQ_Pico
Comm. Format
Data-SINT
Input Assembly Instance:
100
Input Instance Size:
2
Output Assembly Instance:
150
Output Instance Size:
10
Gateway Map: 18A915
E-Flo iQ Advance Map
Comm. Format
Data-SINT
Input Assembly Instance:
100
Input Instance Size:
78
Output Assembly Instance:
150
Output Instance Size:
32