To avoid injury from fire, explosion, or electric
shock, all electrical wiring must be done by a
qualified electrician and comply with all local codes
and regulations.
1.
Ensure that the fused safety switch (B, Fig 2) is
shut off and locked out.
Figure 2 Locked Out Fused Safety Switch
2.
See Fig. 3. Install a start/stop control (C) in the
electrical supply line (A), within easy reach of
the equipment. The start/stop control must be
approved for use in hazardous locations.
3.
Open the electrical compartment (S) on the
motor.
4.
Bring the power wires into the electrical
compartment through the 3/4–14 npt(f) inlet port.
Connect the wires to the terminals, as shown.
Torque the terminal nuts to 25 in-lb (2.8 N•m)
maximum. Do
Do
Do not
not
not over-torque.
over-torque.
over-torque.
5.
Close the electrical compartment. Torque the
cover screws to 15 ft-lb (20.3 N•m).
Figure 3 Connect the Power Wires
Notes
Notes
Notes for
for
for Fig.
Fig.
Fig. 3
3
3
Tighten all terminal nuts to 25 in-lb (2.8 N•m)
maximum. Do
Do
Do not
not
not over
over
over---torque.
torque.
torque.
Tighten cover screws to 15 ft-lb (20.3 N•m).
A conduit seal (D) is required within 18
in. (457 mm) of the motor for the US and
Canada.