External Alarm or Warning Light (Optional)

An external (user supplied) alarm or warning light can 
be added to the Low Level Indicator to provide an audi-
ble or visual signal in a low level situation. 

1.

Connect the DIN connector on the Low Level Indica-
tor to the (user supplied) alarm device. Connection 
is made to PINS 1 and 3 of the DIN, Form “A” Field 
Wireable Adapter. See F

IG

. 14.

2.

Connect Dyna-Star pump to main power source.

3.

Start system following pump start up procedure 
included in the Dyna-Star HP or HF Pump Manual 
provided with your system.

NOTICE

To avoid premature failure and the loss of fluid/low 
level indication:

Do not exceed the rating of the Low Level Sen-
sor Switch by connecting excessive lights or 
audible signals.

Level Sensor Switch is rated for a maximum of 
32 VDC and 10 Watts. Maximum switch current 
is 0.4 AMPS.

F

IG

. 14

Summary of Contents for Dyna-Star HF

Page 1: ...of a low fluid level For professional use only Low Level Indicator Part No 77X522 Includes sight glass electric low level switch and cable Requires follower plate Cannot be used with Auto Fill Shut O...

Page 2: ...sier if the reservoir has been filled with grease first If a follower plate is not pre installed fill tank at least half full 4 Remove plug a from cover b Discard plug you will not reuse it FIG 2 5 Lo...

Page 3: ...servoir Short cable is used with 60 reservoirs Long cable is used with 90 reservoirs Remove and discard the cable you are not using and the Notice label attached to the cables 10 For easy wiring make...

Page 4: ...nst the surface of the follower plate 13 Install follower plate m on top of grease inside res ervoir h with the cone side facing up Press fol lower plate firmly into grease to remove all air pockets 1...

Page 5: ...llower plate m as shown in FIG 10 NOTE When pump is correctly installed the breather t will be below the control box s as shown in FIG 11 17 Replace screws e and washers f and wrench tighten securely...

Page 6: ...to PINS 1 and 3 of the DIN Form A Field Wireable Adapter See FIG 14 2 Connect Dyna Star pump to main power source 3 Start system following pump start up procedure included in the Dyna Star HP or HF Pu...

Page 7: ...red is partially vis ible at the top of the sight glass This appearance indi cates that the lubrication supply container is approaching the low level mark and needs to be refilled Low Level Mark FIG...

Page 8: ...FIG 19 Wrench tighten it in place 3 To determine the level of the fluid remaining in the reservoir loosen and remove dip stick c from res ervoir cover b 4 Use a clean rag to wipe oil grease from end o...

Page 9: ...on low level Operating temperature range 50 F to 150 F 45 C 65 C Electrical Ratings Switching Power 10 Watt Max Switching Current 0 4A Max Switching Voltage 5 32 VDC Contact Resistance 0 150 Initial O...

Reviews: