Installation
Warnings
See the Dyna-Star HP and HF Pump Instruction manual
for additional warnings.
Pressure Relief
Follow the Pressure Relief Procedure whenever
you see this symbol.
To relieve pressure in the system, use two wrenches
working in opposite directions on pump outlet fitting to
slowly loosen fitting only
until fitting is loose and no
more lubricant or air is leaking from fitting. See F
IG
. 1.
Installing Low Level Indicator
1.
Disconnect Dyna-Star pump from main power
source.
2.
If unit has already been in service, relieve pressure
(see Pressure Relief procedure, page 2).
3.
Fill reservoir with grease to raise follower plate (if
installed) to an easily accessible level.
NOTE:
•
Installing the follower plate and low level will be
easier if the reservoir has been filled with
grease first.
•
If a follower plate is not pre-installed, fill tank at
least half full.
4.
Remove plug (a) from cover (b). Discard plug, you
will not reuse it (F
. 2).
5.
Loosen bolts (c) and remove cover (d) from
Dyna-Star pump (F
. 3).
SKIN INJECTION HAZARD
High-pressure fluid from dispense device, hose leaks,
or ruptured components will pierce skin. This may look
like just a cut, but it is a serious injury that can result in
amputation. Get immediate surgical treatment.
Follow Pressure Relief Procedure in this manual,
when you stop dispensing and before cleaning, check-
ing, or servicing equipment.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief
Procedure when you stop dispensing and before
cleaning, checking, or servicing the equipment.