308152
39
Technical Data (King Pumps)
To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow
(lpm/gpm) and operating air pressure (psi/MPa/bar):
1.
Locate desired flow along bottom of chart.
2.
Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale to read fluid outlet
pressure.
To find Pump Air Consumption (m
#
/min or scfm) at a specific fluid
flow (lpm/gpm) and air pressure (psi/MPa/bar):
1.
Locate desired flow along bottom of chart.
2.
Read vertical line up to intersection with selected air consumption
curve (dashes). Follow left to scale to read air consumption.
A
0.6 MPa, 6.3 bar (90 psi) air pressure
B
0.5 MPa, 4.9 bar (70 psi) air pressure
C
0.3 MPa, 2.8 bar (40 psi) air pressure
Performance Charts: Standard King Pumps
0
300
600
900
1200
1500
1800
0
2
4
6
8
10
Fluid Outlet Pressure
13
26
39
psi
MPa, bar
cycles per minute
gpm
liters/minute
22.8
7.6
15.2
FLUID PRESSURE
12.6, 126
6.3, 63
A
B
C
0
45
90
135
180
225
0
2
4
6
8
10
Air Consumption
13
26
39
scfm
m
#
/min
cycles per minute
gpm
liters/minute
7.6
22.8
AIR CONSUMPTION
A
B
C
3.78
2.52
Test Fluid: No. 10 Weight Oil
2.1, 21
38.0
65
52
15.2
1.26
6.30
8.4, 84
4.2, 42
30.4
52
30.4
38.0
65
10.5, 105
5.04
To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow
(lpm/gpm) and operating air pressure (psi/MPa/bar):
1.
Locate desired flow along bottom of chart.
2.
Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale to read fluid outlet
pressure.
To find Pump Air Consumption (m
#
/min or scfm) at a specific fluid
flow (lpm/gpm) and air pressure (psi/MPa/bar):
1.
Locate desired flow along bottom of chart.
2.
Read vertical line up to intersection with selected air consumption
curve (dashes). Follow left to scale to read air consumption.
A
0.6 MPa, 6.3 bar (90 psi) air pressure
B
0.5 MPa, 4.9 bar (70 psi) air pressure
C
0.3 MPa, 2.8 bar (40 psi) air pressure
Performance Charts: Quiet King Pumps
0
300
600
900
1200
1500
1800
0
2
4
6
8
10
Fluid Outlet Pressure
13
26
39
psi
MPa, bar
cycles per minute
gpm
liters/minute
22.8
7.6
15.2
FLUID PRESSURE
12.6, 126
6.3, 63
A
B
C
0
45
90
135
180
225
0
2
4
6
8
10
Air Consumption
13
26
39
scfm
m
#
/min
cycles per minute
gpm
liters/minute
7.6
22.8
AIR CONSUMPTION
A
B
C
3.78
2.52
Test Fluid: No. 10 Weight Oil
2.1, 21
38.0
65
52
15.2
1.26
6.30
8.4, 84
4.2, 42
30.4
52
30.4
38.0
65
10.5, 105
5.04
Summary of Contents for Dura-Flo 2400