Graco C27130 Instructions-Parts List Manual Download Page 6

Service 

6

310547C

Service

Automatic Flow Gun 
Disassembly

This procedure describes how to disassemble the auto-
matic flow gun. Refer to the Parts information on the 
applicable pages while performing the disassembly pro-
cedure. 

NOTE: 

Models C27130 and C27134 are shown in Fig. 

1. The service procedure is basically the same for all 
flow gun models, except where differences are noted.

To disassemble the flow gun, follow this procedure:

1.

Follow the 

Pressure Relief Procedure

 on page 5 to 

relieve the pressure and purge material from the 
gun.

2.

Shut off fluid and air supply lines to the gun. 

3.

Disconnect the fluid and air supply lines from the 
gun. 

4.

While holding the gun body (16) stationary, remove 
the following parts from the gun body. See Fig. 1. 

Model C27151:

 Remove the collar (18) and valve 

seat (19). Remove the adjustment screw (1), nut (2), 
and end cap (10).

All other models:

a.

Remove the collar (18), nozzle (19), and washer 
(9). 

b.

Remove the cylinder cap (10) with the fiber 
washer (1). 

5.

From the nozzle end of the gun, tap the needle (17) 
lightly with a soft rod or dowel until the piston (11) is 
exposed at the rear of the gun body (16). 

6.

Pull the piston (11) and needle (17) from the gun 
body (16). 

Model C27132:

 Remove the spring (20). 

Disassemble the piston and needle as follows:

Model C27151:

 Remove the spring (4). Pull the pis-

ton (11) and needle (17) from the gun body (16). 
Remove the cup (12) from the piston (11). Remove 
the piston (11) from the needle (17). 

All other models:

 

a.

Remove the lock nut (2), washer (3), and piston 
packing (4) from the needle (17). 

b.

Remove the quad ring (12) from the piston (11).

c.

Remove the piston (11) from the needle (17). 

7.

Remove the internal parts from the gun body (16) as 
follows:

Model C27151:

 Follow steps a--d below. Skip step 

e.

All other models:

 

a.

Using a deep well socket wrench, remove the 
packing nut (5). Remove the o-ring (7) from the 
packing nut. 

b.

Using an o-ring pick, remove the packing 
washer (15) from the gun. 

c.

Using an o-ring pick, remove the two seals (13) 
from inside the packing nut (5). Remove the 
o-rings (14) from the seals. 

d.

Using an o-ring pick, remove the o-ring (6) from 
the o-ring groove in the packing nut (5). 

e.

From the cylinder cap end of the gun, tap the 
seal (8) in the nozzle end of the gun body (16) 
lightly with a soft rod or dowel.

Model

Page

C27130

9

C27134

10

C27132 

10

C27151

11

To reduce the risk of serious injury, whenever you are 
instructed to relieve pressure, always follow the 

Pressure Relief Procedure

 on page 5. Also, wear 

eye protection, gloves and protective clothing when 
operating or servicing this flow gun.

Summary of Contents for C27130

Page 1: ...et Pressure 2400 psi 17 MPa 165 bar Maximum Working Fluid Pressure Important Safety Instructions Read all warnings and instructions in this manual Save these instructions Model C27151 12062 shown Tabl...

Page 2: ...rts immediately Do not exceed 100 psi 0 7 MPa 7 bar Maximum Air Inlet Pressure to the gun Do not exceed the 2400 psi 17 MPa 165 bar Maximum Fluid Working Pressure of the gun Do not exceed the maximum...

Page 3: ...OR EXPLOSION HAZARD Improper grounding poor air ventilation open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury Ground the equipment and all othe...

Page 4: ...1 Inspect the flow gun for shipping damage If dam age is found notify the carrier immediately NOTE For C27151 only Remove collar and install 32 series nozzle not included 2 Connect 1 8 npt cylinder p...

Page 5: ...hrough the skin and cause a serious injury To reduce the risk of an injury from injection splashing fluid or moving parts follow the Pressure Relief Procedure whenever you are instructed to relieve th...

Page 6: ...the gun body 16 Model C27132 Remove the spring 20 Disassemble the piston and needle as follows Model C27151 Remove the spring 4 Pull the pis ton 11 and needle 17 from the gun body 16 Remove the cup 1...

Page 7: ...below Skip step a All other models a Tap the seal 8 into place in the gun body 16 lightly with a soft rod or dowel See Fig 1 b Install the o ring 6 in the groove inside the packing nut 5 c Put the o...

Page 8: ...ll the spring 4 6 While holding the gun body 16 stationary fasten the following parts onto the gun body Model C27151 Install the end cap 10 nut 2 and adjustment screw 1 onto the gun body Install the v...

Page 9: ...1 12 C02033 Quad ring 1 13 C02013 Seal 2 14 C20084 O ring ethylene propylene 2 15 C02011 Packing washer 1 16 C27136 Body 1 17 C02007 Needle 1 18 C00004 Collar 1 19 C00008 Nozzle 1 This part is includ...

Page 10: ...0 Cylinder Cap 1 11 C02006 Piston 1 12 C02033 Quad ring 1 13 C02013 Seal 2 14 111710 O ring fluoroelastomer 2 15 C02011 Packing washer 1 16 C27136 Body 1 17 C02007 Needle 1 18 C00004 Collar 1 19 C0800...

Page 11: ...pylene 1 07 C20156 O ring ethylene propylene 1 09 C02018 Valve 1 10 C02000 End cap 1 11 C02001 Piston 1 12 C02003 Cup 1 13 C02013 Seal 2 14 C20084 O ring ethylene propylene 2 15 C02011 Support washer...

Page 12: ...opylene Quantity Part Number Description 1 C20034 Fibre washer 1 114866 Piston packing 1 103337 O ring fluoroelastomer 1 115719 O ring fluoroelastomer 1 C02015 Seal 1 C02033 Quad ring 2 C02013 Seal 2...

Page 13: ...on of the mounting hole is possible verify positions and diameters Model New Old C27130 12060 A C27134 12060 AV C27132 12060 AS C27151 12062 625 2 625 875 1 50 1 0 50 3125 3 75 3 4375 2 9375 2 5 2 125...

Page 14: ...not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS I...

Reviews: