background image

Warnings 

2

310547C

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When 
these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific 
hazard symbols and warnings not covered in this section may appear throughout the body of this manual where 
applicable.

WARNING

WARNING

WARNING

WARNING

EQUIPMENT MISUSE HAZARD

Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result in 
serious injury.

•  This equipment is for professional use only.

•  Read all instruction manuals, warnings, tags, and labels before operating the equipment.

• Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco 

distributor. 

• Do not alter or modify this equipment. Use only genuine Graco parts and accessories.

• Check the equipment daily. Repair or replace worn or damaged parts immediately.

• Do not exceed 100 psi (0.7 MPa, 7 bar) Maximum Air Inlet Pressure to the gun.

• Do not exceed the 2400 psi (17 MPa, 165 bar) Maximum Fluid Working Pressure of the gun.

• Do not exceed the maximum working pressure of any component or accessory used in the system. 

• Route the hoses away from the traffic areas, sharp edges, moving parts, and hot surfaces. Do not 

expose Graco hoses to temperatures above 82° C (180° F) or below -40° C (-40° F).

• Do not use the hoses to pull the equipment. 

• Use fluids and solvents that are chemically compatible with the equipment wetted parts. See the 

Technical Data sections of all the equipment manuals. Always read the material manufacturer’s 
literature before using fluid or solvent in this equipment.

• Always wear protective eyewear, gloves, clothing, and respirator as recommended by the fluid and 

solvent manufacturers. 

• Comply with all applicable local, state and national fire, electrical and other safety regulations. 

• Never use 1,1,1--trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or 

fluids containing such solvents in this equipment. Such use could result in a serious chemical 
reaction, with the possibility of explosion, which could cause death, serious injury, and/or substantial 
property damage.

Summary of Contents for C27130

Page 1: ...et Pressure 2400 psi 17 MPa 165 bar Maximum Working Fluid Pressure Important Safety Instructions Read all warnings and instructions in this manual Save these instructions Model C27151 12062 shown Tabl...

Page 2: ...rts immediately Do not exceed 100 psi 0 7 MPa 7 bar Maximum Air Inlet Pressure to the gun Do not exceed the 2400 psi 17 MPa 165 bar Maximum Fluid Working Pressure of the gun Do not exceed the maximum...

Page 3: ...OR EXPLOSION HAZARD Improper grounding poor air ventilation open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury Ground the equipment and all othe...

Page 4: ...1 Inspect the flow gun for shipping damage If dam age is found notify the carrier immediately NOTE For C27151 only Remove collar and install 32 series nozzle not included 2 Connect 1 8 npt cylinder p...

Page 5: ...hrough the skin and cause a serious injury To reduce the risk of an injury from injection splashing fluid or moving parts follow the Pressure Relief Procedure whenever you are instructed to relieve th...

Page 6: ...the gun body 16 Model C27132 Remove the spring 20 Disassemble the piston and needle as follows Model C27151 Remove the spring 4 Pull the pis ton 11 and needle 17 from the gun body 16 Remove the cup 1...

Page 7: ...below Skip step a All other models a Tap the seal 8 into place in the gun body 16 lightly with a soft rod or dowel See Fig 1 b Install the o ring 6 in the groove inside the packing nut 5 c Put the o...

Page 8: ...ll the spring 4 6 While holding the gun body 16 stationary fasten the following parts onto the gun body Model C27151 Install the end cap 10 nut 2 and adjustment screw 1 onto the gun body Install the v...

Page 9: ...1 12 C02033 Quad ring 1 13 C02013 Seal 2 14 C20084 O ring ethylene propylene 2 15 C02011 Packing washer 1 16 C27136 Body 1 17 C02007 Needle 1 18 C00004 Collar 1 19 C00008 Nozzle 1 This part is includ...

Page 10: ...0 Cylinder Cap 1 11 C02006 Piston 1 12 C02033 Quad ring 1 13 C02013 Seal 2 14 111710 O ring fluoroelastomer 2 15 C02011 Packing washer 1 16 C27136 Body 1 17 C02007 Needle 1 18 C00004 Collar 1 19 C0800...

Page 11: ...pylene 1 07 C20156 O ring ethylene propylene 1 09 C02018 Valve 1 10 C02000 End cap 1 11 C02001 Piston 1 12 C02003 Cup 1 13 C02013 Seal 2 14 C20084 O ring ethylene propylene 2 15 C02011 Support washer...

Page 12: ...opylene Quantity Part Number Description 1 C20034 Fibre washer 1 114866 Piston packing 1 103337 O ring fluoroelastomer 1 115719 O ring fluoroelastomer 1 C02015 Seal 1 C02033 Quad ring 2 C02013 Seal 2...

Page 13: ...on of the mounting hole is possible verify positions and diameters Model New Old C27130 12060 A C27134 12060 AV C27132 12060 AS C27151 12062 625 2 625 875 1 50 1 0 50 3125 3 75 3 4375 2 9375 2 5 2 125...

Page 14: ...not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS I...

Reviews: