Pressure Relief Procedure

1.

Shut off the fluid supply to the flow gun.

2.

Place a waste container beneath the nozzle to catch 
the drainage. 

3.

Actuate the flow gun. Wait until the fluid stops flow-
ing from the hose and gun. 

4.

Shut off power to the fluid supply system. 

If you suspect that the nozzle or hose is completely 
clogged, or that pressure has not been fully relieved 
after following the steps above, very slowly loosen the 
nozzle or hose end coupling to relieve pressure gradu-
ally, then loosen completely. Now clear the nozzle or 
hose.

Troubleshooting

The following table contains troubleshooting information.

The system pressure must be manually relieved to 
prevent the system from starting or spraying 
accidentally. Fluid under high pressure can be injected 
through the skin and cause a serious injury. To reduce 
the risk of an injury from injection, splashing fluid, or 
moving parts, follow the 

Pressure Relief Procedure

 

whenever you:
•  are instructed to relieve the pressure,

•  stop dispensing,

•  check or service any of the system equipment,

•  or install or clean the nozzle.

Problem

Cause(s)

Solution(s)

Gun fails to dispense or shut off 
when actuator is tripped or 
released.

Material lodged in nozzle.

Follow the 

Pressure Relief 

Procedure

 (above). Clear nozzle of 

blockage.

Fluid supply, hose, passages 
clogged.

Check fluid supply settings, hoses, 
etc. for proper material supply.

At initial set up, actuating hoses are 
reversed.

Set up actuating hoses correctly by 
reversing hoses.

Malfunction at actuator and 
four-way valve.

Check actuator and four-way valve 
for proper function.

Air supply inadequate; material 
supply depleted. 

Check air supply and material 
supply.

Gun continues to fail when actuator 
is tripped or released.

Seals and packings are worn.

Rebuild gun as necessary.

Summary of Contents for C27130

Page 1: ...et Pressure 2400 psi 17 MPa 165 bar Maximum Working Fluid Pressure Important Safety Instructions Read all warnings and instructions in this manual Save these instructions Model C27151 12062 shown Tabl...

Page 2: ...rts immediately Do not exceed 100 psi 0 7 MPa 7 bar Maximum Air Inlet Pressure to the gun Do not exceed the 2400 psi 17 MPa 165 bar Maximum Fluid Working Pressure of the gun Do not exceed the maximum...

Page 3: ...OR EXPLOSION HAZARD Improper grounding poor air ventilation open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury Ground the equipment and all othe...

Page 4: ...1 Inspect the flow gun for shipping damage If dam age is found notify the carrier immediately NOTE For C27151 only Remove collar and install 32 series nozzle not included 2 Connect 1 8 npt cylinder p...

Page 5: ...hrough the skin and cause a serious injury To reduce the risk of an injury from injection splashing fluid or moving parts follow the Pressure Relief Procedure whenever you are instructed to relieve th...

Page 6: ...the gun body 16 Model C27132 Remove the spring 20 Disassemble the piston and needle as follows Model C27151 Remove the spring 4 Pull the pis ton 11 and needle 17 from the gun body 16 Remove the cup 1...

Page 7: ...below Skip step a All other models a Tap the seal 8 into place in the gun body 16 lightly with a soft rod or dowel See Fig 1 b Install the o ring 6 in the groove inside the packing nut 5 c Put the o...

Page 8: ...ll the spring 4 6 While holding the gun body 16 stationary fasten the following parts onto the gun body Model C27151 Install the end cap 10 nut 2 and adjustment screw 1 onto the gun body Install the v...

Page 9: ...1 12 C02033 Quad ring 1 13 C02013 Seal 2 14 C20084 O ring ethylene propylene 2 15 C02011 Packing washer 1 16 C27136 Body 1 17 C02007 Needle 1 18 C00004 Collar 1 19 C00008 Nozzle 1 This part is includ...

Page 10: ...0 Cylinder Cap 1 11 C02006 Piston 1 12 C02033 Quad ring 1 13 C02013 Seal 2 14 111710 O ring fluoroelastomer 2 15 C02011 Packing washer 1 16 C27136 Body 1 17 C02007 Needle 1 18 C00004 Collar 1 19 C0800...

Page 11: ...pylene 1 07 C20156 O ring ethylene propylene 1 09 C02018 Valve 1 10 C02000 End cap 1 11 C02001 Piston 1 12 C02003 Cup 1 13 C02013 Seal 2 14 C20084 O ring ethylene propylene 2 15 C02011 Support washer...

Page 12: ...opylene Quantity Part Number Description 1 C20034 Fibre washer 1 114866 Piston packing 1 103337 O ring fluoroelastomer 1 115719 O ring fluoroelastomer 1 C02015 Seal 1 C02033 Quad ring 2 C02013 Seal 2...

Page 13: ...on of the mounting hole is possible verify positions and diameters Model New Old C27130 12060 A C27134 12060 AV C27132 12060 AS C27151 12062 625 2 625 875 1 50 1 0 50 3125 3 75 3 4375 2 9375 2 5 2 125...

Page 14: ...not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS I...

Reviews: