Repair
3A8693B
19
F
IG
. 7: Diaphragm Section
Apply medium-strength (blue) thread locker to the
threads. Torque to 190–220 in-lb (21–25 N•m).
See Torque Sequence, page 29.
1
2
Circular outlet hole must be at
the base of the equipment.
1
1
1
106
1
23
2
2
2
120
101
106
120
101
107