Control Board Replacement
311737G
21
Installation
1.
Position grommet and power cord wires through
strain relief in control board (33).
2.
Reconnect the power cord connectors to the correct
terminals indicated on the control board (120V,
black and white, 240V, blue and brown) on control
board (33).
NOTE:
Be sure power cord is routed between the blue
high pressure hose to the manifold and the sprayer
frame.
3.
Carefully slide control board back into place on the
side of the motor frame.
4.
Replace 3 screws (30). Torque to 30-35 in-lbs
(3.4 - 3.9 N•m).
5.
Reattach motor connector (B) and pressure control
assembly connector (A).
6.
Install shroud (29) and two screws (30) (see illustra-
tion, page 17).
ti6122a
33
Grommet
Strain
Relief
ti6143a
240V
120V
33
33
C
C
Bottom View of Sprayer
ti8322a
Power
Cord
Hose
30
33
ti6119b
ti6143a
240V
120V
33
33
A
B
B
A
Summary of Contents for 311737G