background image

308847          5

Technical Data

Category

Data

Electrical Input Voltage

24 VDC Maximum

Signal Output

0 VDC (OFF)
24 VDC Maximum (ON)

Maximum Fluid Flow

4 gpm (15 liter/min.)

Maximum Operating Pressure

1000 psi (7 MPa, 69 bar)

Inlet/Outlet

1/2 npt

Wiring Gauge Required

18 AWG 2 wire / 90 V

Pulses

5 pulses per pint
10 pulses per quart
(11 pulses per liter)

Summary of Contents for 308847D

Page 1: ...ical Pulse Meter Part No 215474 Measures in pints quarts and gallons Part No 215475 Measures in liters For antifreeze or oil Sends 10 pulses per quart 11 pulses per liter of fluid that flows through the meter 308847D Read warnings and instructions Refer to your Horizont system manual 308607 or Modular Commander system manual 307362 Parts ...

Page 2: ... Cam Wheel Mounting Screws NOTE The normally open micro switch must close each time its roller rides over cam wheel lobes A quart meter has five lobes and a liter meter has ten lobes To find out if micro switch is faulty or needs adjustment see below To check for a faulty micro switch push switch roller arm in all the way and use an ohmmeter or other suitable instrument on soldered terminals of sw...

Page 3: ...ck outer surfaces of piston and inner surfaces of chamber bottom for pitting or scoring and replace these parts if necessary with a com plete meter assembly NOTE Be careful not to damage cam wheel or micro switch or get solvent in switch when servicing fluid piston 6 To assemble insert piston into chamber bottom so the divider plate is centered in slot of piston Turn the pawl pinion on gear box so...

Page 4: ...CKNUT 2 21 102489 SWITCH sensitive Micro switch 1 22 102491 SETSCREW hex socket 2 23 102493 NUT plain hex 2 24 102494 LOCKWASHER 2 25 103178 SCREW mach pnhd 2 26 157229 WASHER flat 1 27 169509 BRACKET switch 1 Ref No Part No Description Qty 28 METER liquid U S quart Cannot be ordered separately 1 METER liquid liter Cannot be ordered separately 1 29 176794 CAM meter Model 215474 only 1 176796 CAM m...

Page 5: ...VDC Maximum Signal Output 0 VDC OFF 24 VDC Maximum ON Maximum Fluid Flow 4 gpm 15 liter min Maximum Operating Pressure 1000 psi 7 MPa 69 bar Inlet Outlet 1 2 npt Wiring Gauge Required 18 AWG 2 wire 90 V Pulses 5 pulses per pint 10 pulses per quart 11 pulses per liter ...

Page 6: ... set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be brought within two 2 years of the date of sale Graco makes no warranty and disclaims all implied warranties of merch...

Reviews: