Setup
3A5278B
17
I/O Signals
Automation Input Signals
This section provides details about the CGM Automation Input and Output signals.
Pump On/Off
Operation Mode
Target Ratio
Provides target volume or weight ratio based on value of System in Weight Mode. Ratio is in thousandths. That is:
1200 = 1.2:1 ratio
1800 = 1.8:1 ratio
Actual Ratio
Provides actual volume or weight ratio based on value of System in Weight Mode. Ratio is in thousandths. That is:
1200 = 1.2:1 ratio
1800 = 1.8:1 ratio
Event Code
Contains the 4 character event code as ASCII characters, but only the most recent to occur. Each of the 4 bytes in
the integer represent one of the ASCII characters in the actual error code. The most significant byte is the first
character.
Values
Pump On/Off
0
Pump is off
1
Pump is on
Values
Operation Mode
0
Spray
1
Run Pump A (recirc)
2
Run Pump B (recirc)
3
Run Pump AB (recirc)
4
Park
5
Pump test
6
Batch dispense
7
Reserved
8
Inactive (system off)
9
Valve test