Repair
3A8570B
17
2. Push the pressure switch wire into the wire clamp
and into the terminal box through the strain relief
3. Twist the strain relief nut on using a wrench until
tightened (F
. 13).
4. Crimp the fork connector to one of the pressure
switch wires (F
5. Connect the crimped wire to E1.
6. Reinsert the second wire back into the connector
containing the yellow and white cables (F
7. Place the gasket onto the terminal box.
8. Replace the terminal box cover.
9. Insert the four terminal box cover screws and
tighten (F
. 14).
information
beginning on page 9.
Pump Housing Assembly P/N
133373
Disassembly
1. Follow
2. Turn off and disconnect the power to the pump.
3. Remove the pump from the tank.
4. Remove the suction tube from the pump.
5. Remove the four terminal box cover screws (F
15).
F
IG
. 13
E1
Strain Relief Nut
Strain Relief
F
IG
. 14
terminal Box