background image

All written and visual data contained in this document reflects the latest product information available at the time of publication. 

Graco reserves the right to make changes at any time without notice.

Original instructions. This manual contains English. MM 3A8551

Graco Headquarters: 

Minneapolis

International Offices: 

Belgium, China, Japan, Korea

GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA

Copyright 2021, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.

www.graco.com

Revision B, 

August 2021

 

Graco Extended Warranty

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of 

sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a 

period of twenty four months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This 

warranty applies only when the equipment is installed, operated and maintained in accordance with Graco's written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty 

installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of 

non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with 

structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or 

maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification 

of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be 

returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or 

workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO 

WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. 
Graco's sole obligation and buyer's sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy 

(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental 

or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale Graco makes 

no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, 

equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric 

motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance 

in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, 

or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the 

negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered 

into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu 

que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés 

à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.

Graco Information

For the latest information about Graco products, visit

 

www.graco.com

.

For patent information, see

 

www.graco.com/patents

.

TO PLACE AN ORDER,

 contact your Graco distributor or call to identify the nearest distributor.

Phone:

 612-623-6928 

or Toll Free:

 1-800-533-9655, 

Fax:

 612-378-3590

Summary of Contents for 25T461

Page 1: ...RD Misuse can cause death or serious injury Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards Make sure all equipment is rated and approved for the environment in which you are using it Use equipment only for its intended purpose Call your distributor for information Keep children and animals away from work area Comply with all applic...

Page 2: ...FIG 1 2 Keep holding the magnet to the Hot Spot The LED will flash green and then flash red Then the red light will stay lit 3 Remove the magnet 4 While the red light is illuminated a series of beeps occur as the device connects 5 Successfully connecting is indicated by a high low high series of beeps that indicate the data is being sent to Pulse Level The LED turns green after data is successfull...

Page 3: ...eal make sure that the device is vertical on the tank that it is secured correctly to the base and that the threads have not crossed NOTE If the tank does not contain a suitably positioned opening at the top of the tank reference Drilling page 4 LED Pattern Function LED Test when a magnet is held against the hot spot the LED is briefly green followed by briefly red then the LED is off Red LED Lit ...

Page 4: ...e positioned opening at the top of the tank it will be necessary to manually drill into the top of the tank 1 Select a flat area on the top of the tank located towards the center FIG 3 2 Drill a 1 5 in bsp hole at the selected area using a 45 5 mm tapping drill 3 Continue with Activation FIG 3 ...

Page 5: ...rs creating a connection between the TLM and the Pulse Level to load the configuration FIG 4 NOTE Frequent measurements results in shorter battery life Manual Measurement 1 Hold the magnet supplied to the Hot Spot directly under the LED to activate the device FIG 1 2 Keep holding the magnet to the Hot Spot The LED will flash green and then flash red Then the red light will stay lit 3 Remove the ma...

Page 6: ...mantle and recycle it in a responsible manner Remove batteries circuit boards LCDs liquid crystal displays and other electronic components Recycle according to applicable regulations Do not dispose of batteries or electronic components with household or commercial waste Deliver remaining product to a recycling facility ...

Page 7: ... Weak or dead batteries Replace batteries See Replace Batteries page 8 Tank Level Monitor was not associated with a tank in software Assign TLM serial number to tank Reading is scheduled when pump is operating Ensure readings are scheduled during times that the pump is not operating LED will not turn on Magnet removed too soon Hold magnet to device hot spot for a longer period of time Try using a ...

Page 8: ...adings 1 Remove the TLM from the tank by unscrewing it from the opening 2 Remove the four 4 screws that keep the case together FIG 6 3 Verify that the device is right side up before opening to prevent the batteries from falling out FIG 7 4 Replace the four 4 C cell Alkaline batteries FIG 8 WARNING Fire and Explosion Hazard Sparking can occur when changing batteries Only replace the batteries in a ...

Page 9: ... sure that the gasket is placed correctly FIG 9 6 Reconnect the two halves then replace the four 4 screws 7 Re install the TLM back into the tank opening 8 Take a manual measurement to verify the TLM is activated FIG 9 Gasket ...

Page 10: ... gallons or liters Tank end walls must be flat they cannot be any other shape including belled Obround Tank Maximum volume 999 999 gallons or liters Tank end walls must be flat they cannot be any other shape including belled Non Standard Tanks Maximum volume 999 000 gallons or liters Define strapping table in Pulse Level software Up to 100 strapping table points to correlate tank fluid height to v...

Page 11: ...30 7 g with batteries RF Frequency Band LTE CAT M1 Operating Temperature Range 0 F to 122 F 17 8 C to 50 C Storage Temperature Range 22 F to 140 F 30 C to 60 C Batteries 4 x Alkaline C cell Battery Life 5 years Enclosure Ingress Protection IP67 Tanks Maximum Volume 999 999 gallons 999 999 liters Maximum Height 13 ft 400 cm Altitude 6 000 ft 2 km The battery life is based upon four 4 measurements p...

Page 12: ...kmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as ...

Reviews: