Identify a threaded opening on the top of the tank for the 

device to be installed. The location should be vertical 

with a clear path to the contents of the tank. There 

should be no obstructions that could interfere with the 

signal. Insert the threaded device by screwing it into the 

opening. Do not over tighten.

1. If the hole is not threaded, place the foam gasket 

(included with kit) over the opening.

2. Place the mounting adapter (included with kit) on 

top of the foam gasket.

3. Use the two (2) stainless steel self-tapping, 

counter-sunk screws (included with kit) to attach the 

adapter to the tank. Do not over tighten.

4. Attach the device to the adapter. To form a secure 

seal, make sure that the device is vertical on the 

tank, that it is secured correctly to the base, and that 

the threads have not crossed.

NOTE: If the tank does not contain a suitably positioned 

opening at the top of the tank, reference 

Drilling

, page 

4.

LED Pattern

Function

LED Test: when a magnet is held 

against the hot spot, the LED is 

briefly green, followed by briefly 

red, then the LED is off.

Red LED Lit

Modem Busy: registering on the 

network and sending data.

Green LED Lit

Activated: the server has 

responded and activated the 

server.

Beep Pattern

Definition

Low beep once per 

second

Network registration

High beep once per 

second

TCP connecting

Low beep once every four 

(4) seconds

Network / TCP listen for 

commands

Low beep once every two 

(2) seconds

Re-establish network / TCP

High /Low combination 

beep

Incoming data

Low / High combination 

beep

Outgoing data

Low double beep every 

four (4) seconds

Network listen (data 

received and the device is 

active)

F

IG

. 2

Summary of Contents for 25T461

Page 1: ...RD Misuse can cause death or serious injury Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards Make sure all equipment is rated and approved for the environment in which you are using it Use equipment only for its intended purpose Call your distributor for information Keep children and animals away from work area Comply with all applic...

Page 2: ...FIG 1 2 Keep holding the magnet to the Hot Spot The LED will flash green and then flash red Then the red light will stay lit 3 Remove the magnet 4 While the red light is illuminated a series of beeps occur as the device connects 5 Successfully connecting is indicated by a high low high series of beeps that indicate the data is being sent to Pulse Level The LED turns green after data is successfull...

Page 3: ...eal make sure that the device is vertical on the tank that it is secured correctly to the base and that the threads have not crossed NOTE If the tank does not contain a suitably positioned opening at the top of the tank reference Drilling page 4 LED Pattern Function LED Test when a magnet is held against the hot spot the LED is briefly green followed by briefly red then the LED is off Red LED Lit ...

Page 4: ...e positioned opening at the top of the tank it will be necessary to manually drill into the top of the tank 1 Select a flat area on the top of the tank located towards the center FIG 3 2 Drill a 1 5 in bsp hole at the selected area using a 45 5 mm tapping drill 3 Continue with Activation FIG 3 ...

Page 5: ...rs creating a connection between the TLM and the Pulse Level to load the configuration FIG 4 NOTE Frequent measurements results in shorter battery life Manual Measurement 1 Hold the magnet supplied to the Hot Spot directly under the LED to activate the device FIG 1 2 Keep holding the magnet to the Hot Spot The LED will flash green and then flash red Then the red light will stay lit 3 Remove the ma...

Page 6: ...mantle and recycle it in a responsible manner Remove batteries circuit boards LCDs liquid crystal displays and other electronic components Recycle according to applicable regulations Do not dispose of batteries or electronic components with household or commercial waste Deliver remaining product to a recycling facility ...

Page 7: ... Weak or dead batteries Replace batteries See Replace Batteries page 8 Tank Level Monitor was not associated with a tank in software Assign TLM serial number to tank Reading is scheduled when pump is operating Ensure readings are scheduled during times that the pump is not operating LED will not turn on Magnet removed too soon Hold magnet to device hot spot for a longer period of time Try using a ...

Page 8: ...adings 1 Remove the TLM from the tank by unscrewing it from the opening 2 Remove the four 4 screws that keep the case together FIG 6 3 Verify that the device is right side up before opening to prevent the batteries from falling out FIG 7 4 Replace the four 4 C cell Alkaline batteries FIG 8 WARNING Fire and Explosion Hazard Sparking can occur when changing batteries Only replace the batteries in a ...

Page 9: ... sure that the gasket is placed correctly FIG 9 6 Reconnect the two halves then replace the four 4 screws 7 Re install the TLM back into the tank opening 8 Take a manual measurement to verify the TLM is activated FIG 9 Gasket ...

Page 10: ... gallons or liters Tank end walls must be flat they cannot be any other shape including belled Obround Tank Maximum volume 999 999 gallons or liters Tank end walls must be flat they cannot be any other shape including belled Non Standard Tanks Maximum volume 999 000 gallons or liters Define strapping table in Pulse Level software Up to 100 strapping table points to correlate tank fluid height to v...

Page 11: ...30 7 g with batteries RF Frequency Band LTE CAT M1 Operating Temperature Range 0 F to 122 F 17 8 C to 50 C Storage Temperature Range 22 F to 140 F 30 C to 60 C Batteries 4 x Alkaline C cell Battery Life 5 years Enclosure Ingress Protection IP67 Tanks Maximum Volume 999 999 gallons 999 999 liters Maximum Height 13 ft 400 cm Altitude 6 000 ft 2 km The battery life is based upon four 4 measurements p...

Page 12: ...kmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as ...