background image

Overview

3A5538F

7

Overview

The Reactor Connect allows the Graco Reactor 2 to be 
monitored and operated remotely. The Reactor 2 is 
intended to be controlled by an on-site operator. In any 
lock-out, tag-out procedure, take into consideration the 
potential for changes to the Reactor 2 settings due to 
remote operation.

Installation

Mount Cellular Module

1. Shut down the system. See your Reactor 2 

operation manual for shutdown instructions.

2. Disconnect incoming power at the source.

3. Open the top and bottom door latches to the 

electrical cabinet.

4. Open the electrical cabinet.

5. Install the cellular module (A) at the top of the 

electrical enclosure using screws (7) and nuts (5).

6. Attach the antenna cable (B) to the cellular module 

(A) and the antenna bulkhead (E). Tighten by hand.

7. Remove the power supply cable (D) from the motor 

or hydraulic control module (MCM or HCM). Attach 
the cable to the cellular module.

8. Attach the CAN cable (F) to the cellular module (A) 

and the motor or hydraulic control module (MCM or 
HCM).

9. Close and lock the electrical cabinet door with the 

door latches.

10. Install the antenna (C) onto the antenna bulkhead 

(E) on top of the electrical cabinet. Tighten by hand.

To avoid injury due to unexpected machine operation 
initiated by remote controller, disconnect the cellular 
module from the system prior to troubleshooting. See 

Disconnect Cellular Module

, page 11.

Summary of Contents for 25M777

Page 1: ...25M777 Model 25P159 Important Safety Instructions Read all warnings and instructions in this manual and in the Reactor 2 manual Save all instructions IMPORTANT By operating your Reactor 2 system with...

Page 2: ...Graco Standard Warranty 14 Graco Information 14 Models Related Manuals Agency Approvals NOTE Cellular module kit 25M833 contains Part 25M720 Cellular module kit 25E658 contains Part 25N372 Kit Include...

Page 3: ...Agency Approvals 3A5538F 3 Description Approvals MODULE cellular worldwide 25M720 MODULE cellular United States and Canada only 25N372...

Page 4: ...are compatible with equipment wetted parts See Technical Specifications in all equipment manuals Read fluid and solvent manufacturer s warnings For complete information about your material request Saf...

Page 5: ...ypical Reactor Connect Cell Module Installation Reactor 2 Electric WL D A D F C E B MCM Ref Description A Cellular Module B Antenna Cable C Antenna D Power Supply Cable E Antenna Bulkhead F CAN Cable...

Page 6: ...l Reactor Connect Cell Module Installation Reactor 2 Hydraulic WL D 0 Ref Description A Cellular Module B Antenna Cable C Antenna D Power Supply Cable E Antenna Bulkhead F CAN Cable HCM Hydraulic Cont...

Page 7: ...the cellular module A at the top of the electrical enclosure using screws 7 and nuts 5 6 Attach the antenna cable B to the cellular module A and the antenna bulkhead E Tighten by hand 7 Remove the po...

Page 8: ...re connecting the Reactor to an app for the first time Reset Reactor Key See page 10 3 To connect the app to the Reactor scan the code a Select the Scan code button on the app See FIG 3 b Using the ap...

Page 9: ...r Name J Menu K Reactor Power Switch L Heat Zone Settings M Heat Zone On Off N Heat Zone Actual Temperature P Heat Zone Temperature Setpoint R Proportioner Start Stop Switch S Proportioner Mode Spray...

Page 10: ...remotely changing or viewing Reactor settings without first reconnecting to the Reactor 1 On the Reactor ADM Cellular screen press to reset the Reactor key 2 Press to confirm resetting the Reactor key...

Page 11: ...loose end of the power supply cable D to the motor or hydraulic control module MCM or HCM 7 Close and lock the electrical cabinet door with the door latches Problem Cause Solution No module status LE...

Page 12: ...1 25M833 KIT cellular module worldwide 1 25E658 KIT cellular module United States and Canada only 1 2 25M830 CABLE antenna 1 4 25M828 ANTENNA paddle 1 5 127158 NUT 8 32 2 6 123422 CABLE can 1 7 16X12...

Page 13: ...U201 Band Support Band 19 800 MHz Band 5 850 MHz Band 8 900 MHz Band 2 1900 MHz Band 1 2100 MHz WCDMA HSDPA HSUPA Power Class Power Class 3 24 dBm for WCDMA HSDPA HSUPA mode Cellular Module 25N372 FC...

Page 14: ...n material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRA...

Reviews: