Troubleshooting
Error
Code
Error
Position
Type
Name
Cause
Solution
T4DH Hose
ALARM
High Chemical
Temperature
Bad High Power
Temperature Control
Module.
Replace HPTCM. See
System Repair manual.
Broken Fan.
Check fan relay (K4) and
fuse (30 Amp ATO “F3”) on
load center board. Replace
if needed.
T4DE Heat
Exchanger
ALARM
High Temperature
Coolant Outlet
Plugged radiator.
Replace if needed.
Cooling fans are not
operating properly.
Ensure ambient temperature
is less than 120°F(48°C).
Check to see that the fans
are moving. Measure
voltage to fans. There
should be 240 VAC. If no
voltage is measured, check
wiring between fan and
circuit breaker CB03.
If the fans have voltage but
are not moving, replace fan.
Use an air hose to blow out
around the fan housings and
remove any built-up debris.
T4NM MCM
ALARM
High Motor
Temperature
Bad electric motor.
Replace electric motor. See
System Repair manual.
82
3A1705E