Warnings

3A3006F

5

EQUIPMENT MISUSE HAZARD

 

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system 
component. Se

Technical Specifications

 in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See 

Technical 

Specifications

 in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For 

complete information about your material, request Safety Data Sheets (SDSs) from distributor or 
retailer.

Turn off all equipment and follow the 

Pressure Relief Procedure 

when equipment is not in use.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine 
manufacturer’s replacement parts only.

Do not alter or modify equipment. Alterations or modifications may void agency approvals and create 
safety hazards.

Make sure all equipment is rated and approved for the environment in which you are using it.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

MOVING PARTS HAZARD

Moving parts can pinch, cut or amputate fingers and other body parts.

Keep clear of moving parts.

Do not operate equipment with protective guards or covers removed.

Equipment can start without warning. Before checking, moving, or servicing equipment, follow the 

Pressure Relief Procedure

 and disconnect all power sources.

PERSONAL PROTECTIVE EQUIPMENT

Wear appropriate protective equipment when in the work area to help prevent serious injury, including 
eye injury, hearing loss, inhalation of toxic fumes, and burns. Protective equipment includes but is not 
limited to:

Protective eyewear, and hearing protection. 

Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.

WARNING

Summary of Contents for 24W633

Page 1: ...ive and non abrasive oils and lubricants For professional use only Maximum Input 1800 RPM Drive Ratio 118 1 Models page 3 Related Manuals Important Safety Instructions Read all warnings and instructio...

Page 2: ...Operation 8 Pressure Relief Procedure 8 Break In Period 8 Maintenance 9 Lube Refill Replace 9 Recycling and Disposal 10 End of Product Life 10 Troubleshooting 11 Parts 12 Accessories 13 Pumps 13 Other...

Page 3: ...ly 6 Pint LH NA 25R555 Box Lubricator 4 Pint 3 8 in pump RH 3 3500 25R559 Box Lubricator 4 Pint 3 8 in pump LH 3 3500 25R554 Box Lubricator 6 Pint 3 8 in pump RH 5 3500 25R558 Box Lubricator 6 Pint 3...

Page 4: ...leaks with your hand body glove or rag Follow the Pressure Relief Procedure when you stop dispensing and before cleaning checking or servicing equipment Tighten all fluid connections before operating...

Page 5: ...e sure all equipment is rated and approved for the environment in which you are using it Use equipment only for its intended purpose Call your distributor for information Route hoses and cables away f...

Page 6: ...nent Identification Key A Sight Glass B Drain Plug C Fill Cover D Pump Mounting Screws The GBL 7500 Box Lubricator Pump and GBL Alarm Pump are available from Graco See Accessories page 13 for informat...

Page 7: ...l it reaches the FULL line on the Sight Glass A NOTE Filter the oil with a minimum 25 micron strainer Depending upon machine requirements it may be necessary to maintain a higher cleanliness level A b...

Page 8: ...the Sight Glass A with SAE 30 to SAE 40 weight gear lube Run normally and change the gear lube after the two week break in period FIG 2 This equipment stays pressurized until pressure is manually reli...

Page 9: ...dipping in solvent and blowing dry using compressed air d Reinstall the pumps and tighten torque 110 in lb 10 in lb 12 43 N m 1 13 N m e Apply thread sealant user supplied to the Drain Plug B reinsta...

Page 10: ...d of the product s useful life dismantle and recycle it in a responsible manner Perform the Pressure Relief Procedure Drain and dispose of fluids according to applicable regulations Refer to the mater...

Page 11: ...Refill Replace page 9 Check the Drain Plug and tighten if needed No flow from pump outlets The camshaft is not rotating because the rotary power source is defective Repair replace the rotary power sou...

Page 12: ...nd 24W636 1 17D149 GASKET cover not shown models 24W634 and 24W635 1 9 556732 GASKET pump models 24W633 and 24W636 5 GASKET pump models 24W634 and 24W635 7 10 557128 PLATE blank models 24W633 and 24W6...

Page 13: ...8 in Pressure Fed Pump 24K466 Alarm Pump Part No Description Special Features Notes 559037 Gravity Supply Mounted in the last pump station Exception is when an Alarm Pump is used then this option is m...

Page 14: ...3 24W636 25R513 25R555 25R557 25R559 4 Pints Models 24W634 24W635 25R514 25R554 25R556 25R558 6 Pints Temperature Operating Temperature Range Non ATEX 20 F to 140 F 29 C to 60 C Operating Temperature...

Page 15: ...Reservoir and Mounting Dimensions 3A3006F 15 Reservoir and Mounting Dimensions Dimensions are shown in inches mm See Dimensions Table page 16...

Page 16: ...m inch mm inch mm 24W633 25R513 Lubricator Reservoir 4 Pint NA NA 14 25 361 95 7 24 183 90 5 5 139 7 1 74 44 20 24W636 25R555 25R557 25R559 Box Lubricator 4 Pint 9 67 245 62 24W634 25R514 Lubricator R...

Page 17: ...Reservoir and Mounting Dimensions 3A3006F 17 California Proposition 65 CALIFORNIA RESIDENTS WARNING Cancer and reproductive harm www P65warnings ca gov...

Page 18: ...erial or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES...