Maintenance
334198K
15
Maintenance
Monthly Maintenance
Periodically (approximately once a month) inspect the
ram guide sleeves, rods, and cylinders for wear or dam-
age; replace all worn parts.
Check the hydraulic fluid level. Add more hydraulic fluid
if the fluid level falls lower than 4 in. (102 mm) from the
top of the fluid gauge. See
Checking the Hydraulic Fluid
Level
Check the hydraulic fluid level in the supply unit. The
fluid level should be approximately 2–4 in. (51–102 mm)
from the top of the fluid level gauge (3). If necessary,
perform the following steps to add more hydraulic fluid:
1. Unscrew the breather (4).
2. Pour hydraulic fluid through the breather hole (13).
3. Replace the breather. See F
NOTE:
Make sure hydraulic tank is filled to the correct
level. Overfilling tank can cause hydraulic fluid to spill
out the breather. See F
Changing the Hydraulic Fluid
Filter
The filter element (19) of the hydraulic fluid assembly
may become clogged with manufacturing residue after
the first 40 hours of operation. Change the filter element
after the first 40 hours of operation. For information
about starting up the rest of the system, refer to the
Therm-O-Flow 200 and Therm-O-Flow 20, Instruc-
tions-Parts manuals. See F
F
IG
. 11
WLE
F
IG
. 12
F
IG
. 13
FILL
LEVEL
Over Filled
Correctly
Filled
Under Filled
WLD