![Graco 24N950 Operation - Repair - Parts Download Page 17](http://html1.mh-extra.com/html/graco/24n950/24n950_operation-repair-parts_2251626017.webp)
Shutdown and Cleaning
332119E
17
Unclogging Spray Tip/Guard Assembly
1. Perform
Pressure Relief Procedure
, page 10.
2. Reverse spray tip (X) to UNCLOG position.
3. Put prime/spray valve (D) DOWN to spray position.
4. Push spray button (A) to start field marker and clear
clog.
5. Push spray button again to stop field marker.
6. Perform
Pressure Relief Procedure
, page 10.
7. Rotate spray tip (X) back to SPRAY position.
8. Put prime/spray valve DOWN to spray position.
9. Push prime/spray button to start sprayer and resume
spraying.
10. If spray tip is still clogged, you may have to repeat
steps 1 - 9 several times.
11. If material still fails to be sprayed, perform
Pressure
Relief Procedure
, page 10.
12. Perform
Tip Removal Cleaning
, page 19.
13. Perform
Filter Removal/Cleaning
, page 11.
14. If applicable, perform
CleanShot Cleaning
, page 19.
Always perform
Pressure Relief Procedure
before
unclogging spray tip/guard assembly.
ti20183a
ti20192a
X
ti20184a
D
ti20212a
A
ti20191a
X